21
NOTE:
Use 30 mbar regulator and its corresponding injector size for butane/propane under the category I3B/P(30).
Use 30 mbar regulator and its corresponding injector size for butane under the category I3+(28-30/37).
Use 37 mbar regulator and its corresponding injector size for propane under the category I3+(28-30/37).
Use 50 mbar regulator and its corresponding injector size for butane/propane under the category I3B/P(50).
Marking on the injector indicate the injector size. For example, "0.90" means the injector size is 0.90 mm.
Country
Gas Type
Pressure
BE, FR, IT, LU, IE, GB, GR, PT, ES, CZ, CH, SI
I3+
28-30/37 mbar
BG, CY, CZ, DK, EE, FI, HU, IS, LT, LV, MT, IT, NL, NO, RO, SK, SE, SI
I3B/P
30 mbar
PL
I3P
37 mbar
AT, CH, CZ, DE
I3B/P
50 mbar
*Country codes are in accordance with EN ISO 3166-1:2006.
European Gas Pressures and Specifications
Nexgrill Industries, Inc.
14050 Laurelwood Pl Chino, CA 91710 USA
Model
860-0003C
Appliance category
I
3+(28-30/37)
I
3B/P(30)
I
3B/P(37)
I
3B/P(50)
Type of gas
Butane
Propane
Butane, Propane or their mixture
Gas pressure (mbar)
28-30
37
30
37
50
Main Burner Injector size (Ø mm)
0.85
0.85
0.81
0.76
Rear Burner Injector size (Ø mm)
0.90
0.90
0.83
0.80
Sear Burner Injector size (Ø mm)
0.92
0.92
0.84
0.81
Side Burner Injector size (Ø mm)
0.90
0.90
0.83
0.80
Nominal heat input (Hs) (kW)
Total: 27.75
Gas consumption (g/h) (total)
Butane - Total: 2019
Propane - Total: 1983