Electrical Requirements - Canada Only

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the CSA Standard C22.1, Canadian 
Electrical Code, Part 1 - latest edition, and all local codes and 
ordinances.

A copy of the above code standards can be obtained from:

Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.

Do not ground to a gas pipe.

Check with a qualified electrical installer if you are not sure 
the range is properly grounded.

Do not have a fuse in the neutral or ground circuit.

When a 4-wire, single phase 208/240 volt, 60 Hz., AC only 
electrical supply is available, a 30-amp minimum circuit 
protection is required, fused on both sides of the line.

A time-delay fuse or circuit breaker is recommended.

This range is equipped with a CSA International Certified 
Power Cord intended to be plugged into a standard 14-50R 
wall receptacle. Be sure the wall receptacle is within reach of 
range’s final location.

Do not use an extension cord.

Gas Supply Requirements

Observe all governing codes and ordinances. 

IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 

IMPORTANT: Range cooktop must be connected to a regulated 
gas supply.

Type of Gas 

Natural Gas:

This range is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 

This range is factory set for use with Natural gas. The model/
serial rating plate located on the right vertical surface of the 
oven door frame has information on the types of gas that can 
be used. If the types of gas listed do not include the type of 
gas available, check with the local gas supplier.

LP Gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. To convert to LP 
gas, use the LP gas conversion kit provided with your range. The 
parts for this kit are in the literature package supplied with the 
range.

WARNING

Electrical Shock Hazard

Electrically ground range.

Failure to do so can result in death, fire, or 
electrical shock.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Summary of Contents for Dual Fuel Convection Range

Page 1: ...ble des matières 2 9760618 OFF O F F OFF O F F OFF OFF OFF OFF IMPORTANT Save for local electrical inspector s use Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT À conserver pour consultation par l inspecteur local des installations électriques Installateur Remettre les instructions d installation au propriétaire...

Page 2: ...9 Installation de la bride antibasculement 19 Fixation du dosseret ou de la garniture en îlot 20 Raccordement à la canalisation de gaz 21 Système d allumage électronique 21 Réinstallation de l évent du fond 22 Achever l installation 22 SCHÉMAS DE CÂBLAGE 23 RANGE SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All sa...

Page 3: ...lier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier In the State of Massachusetts the following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts If using a ball valve it shall be a ...

Page 4: ...t seal the range to the side cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The wall anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas S...

Page 5: ... right vertical surface of the oven door frame Range must be connected to a grounded metal permanent wiring system A 4 wire or 3 wire single phase 208 240 volt 60 Hz AC only electrical supply is required on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended The fuse size must not exceed the circuit rating of the range specified on the mode...

Page 6: ...erican National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Range cooktop must be connected to a regulated gas supply Type of Gas Natural Gas This range is design certified by CSA International for use with Natural gas or after proper conversion for use with LP gas This range is factory set for use with Natural gas The model serial rating pla...

Page 7: ... to the range It should be in a location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the range Gas Pressure Regulator The gas pressure regulator supplied with this range must be used The inlet pressure to the regulator should be as follows for proper operation Natural Gas Minimum pressure 6 15 2 cm WCP Maximum pres...

Page 8: ... Oven must be level for satisfactory baking performance InstallAnti TipBracket 1 Choose the correct anti tip bracket for your installation If the wall behind the range has no baseboard or has a baseboard up to 0 95 cm thick use the shorter 1 2 5 cm anti tip bracket If the wall behind the range has a baseboard thicker than 0 95 cm use the longer 1 4 4 cm anti tip bracket 2 Locate a stud on the wall...

Page 9: ...t power 2 Remove junction box cover if present 3 Connect the 4 wire flexible cable from the range to the junction box using a UL listed or CSA approved conduit connector 4 Tighten screws on conduit connector if present 5 Connect the two black wires together using the UL listed wire nuts 6 Connect the two white wires together using the UL listed wire nuts 7 Connect the green or bare ground wire fro...

Page 10: ...the ground Slide range toward the wall until the rear brace is under the anti tip bracket Stand range up making sure the anti tip bracket catches the rear brace MakeGasConnection 1 Assemble flexible connector from gas supply pipe to pressure regulator located in the middle front of the range 2 Apply pipe joint compound made for use with LP gas to the smaller thread ends of the flexible connector a...

Page 11: ...e gas shutoff valves are set to the open position Check that burner caps are properly positioned on burner bases Repeat start up If a burner does not light at this point contact your dealer or authorized service company for assistance Adjust Flame Height Adjust the height of top burner flames The cooktop low burner flame should be a steady blue flame approximately 0 64 cm high The flame can be adj...

Page 12: ...t backguard or island trim is installed If horizontal clearance to combustible materials behind cooking surface is less than 1 2 5 cm 6 Check that the range is connected only to the type of gas for which it is certified for use 7 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by protective shipping material Dry thoroughly with a soft cloth For more inf...

Page 13: ...13 Oven Schematic Blower remains off until oven reaches 190 F 88 C and may continue running up to 45 minutes after oven has turned off NOTE Circuit is shown in standby off mode with oven door closed ...

Page 14: ...rité les renseignements dans ce manuel doivent être observés pour réduire au minimum les risques d incendie ou d explosion ou pour éviter des dommages au produit des blessures ou un décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter ...

Page 15: ...u dessus de la cuisinière Dans le cas d une cuisinière encastrée l enceinte doit recouvrir complètement les côtés et l arrière de la cuisinière Afin de supprimer le risque de brûlures ou d incendie en se penchant au dessus des unités de surface chauffées le rangement en armoire au dessus des unités de chauffage doit être évité Si le rangement en armoire est envisagé le risque peut être réduit par ...

Page 16: ...au Canada il est nécessaire de faire pivoter la prise de 90 REMARQUE Distance de séparation de 42 106 7 cm ou plus lorsque le fond d un placard de bois ou de métal est protégé par une planche ignifugée d au moins 0 64 cm recouverte d une feuille métallique d épaisseur égale ou supérieure à acier calibre 28 MSG acier inoxydable 0 015 0 4 mm aluminium 0 024 0 6 mm ou cuivre 0 020 0 5 mm Distance de ...

Page 17: ...l installation doit satisfaire aux prescriptions de la plus récente édition du code national en vigueur National Fuel Gas Code ANSI Z223 1 American National Standard ou CAN CGA B149 IMPORTANT La table de cuisson de la cuisinière doit être raccordée à une source d alimentation en gaz régulée Type de gaz Gaz naturel La conception de cette cuisinière a été homologuée par CSA International pour l alim...

Page 18: ...anuel doit être séparé de la cuisinière mais doit se trouver dans la même pièce en un endroit où il sera facilement accessible pour les manoeuvres d ouverture fermeture Ne pas entraver l accès au robinet d arrêt manuel Le robinet d arrêt manuel est prévu pour ouvrir ou fermer l alimentation en gaz de la cuisinière Détendeur de gaz Le détendeur fourni avec cette cuisinière doit être utilisé Pour un...

Page 19: ...urner les manchons des pieds de nivellement pour mettre la cuisinière d aplomb et pour soulever ou abaisser la cuisinière à la hauteur de comptoir désirée REMARQUE Le four doit être d aplomb pour pouvoir obtenir des résultats de cuisson satisfaisants Installationdelabrideantibasculement 1 Choisir la bride antibasculement correcte pour votre installation Si le mur derrière la cuisinière ne comporte...

Page 20: ...verture d encastrement 2 Retirer le carton ou le panneau de fibre dur de sous la cuisinière Déplacer la cuisinière à son emplacement final 3 Fixer le dosseret ou la garniture en îlot en fonction des exigences de l installation Voir Outillage et pièces Des vis de fixation sont incluses dans le sachet de documentation Fixation du dosseret Fixation de la garniture en îlot 4 À l aide de 2 personnes ou...

Page 21: ...églages des flammes Un système d allumage électronique est utilisé à la place des flammes de veille usuelles pour l allumage des brûleurs table de cuisson et four Lorsqu on place le bouton de commande d un brûleur de la table de cuisson à la position LITE allumage le système génère une étincelle pour l allumage du brûleur La génération d étincelles se poursuit aussi longtemps que le bouton de comm...

Page 22: ...rs sur les chapeaux de brûleurs La plaque de mijotage peut reposer sur l une des grilles ou être remisée pour utilisation ultérieure Réinstallationdel éventdufond 1 Insérer les languettes de la partie inférieure de l évent dans les fentes de la garniture avant 2 Pousser l évent vers le haut pour que les trous soient alignés avec la partie supérieure de l évent 3 Fixer à nouveau l évent à l aide de...

Page 23: ...e les débrancher lors d une intervention sur le module de commande Une erreur de rebranchement pourrait provoquer un fonctionnement incorrect et une situation dangereuse Vérifier le bon fonctionnement de l appareil après l intervention Schéma de câblage de la table de cuisson ...

Page 24: ... éteint REMARQUE Circuit illustré en mode d attente arrêt avec porte du four fermée 9760618 2005 All rights reserved Tous droits réservés Registered Trademark TM Trademark of KitchenAid U S A KitchenAid Canada licensee in Canada Marque déposée TM Marque de commerce de KitchenAid U S A Emploi licencié par KitchenAid Canada au Canada 10 05 Printed in U S A Imprimé aux É U ...

Reviews: