10
6.
Pour one bottle of solution into the water pan. Fill the bottle
twice with tap water and pour it into the water pan.
7.
Push the selector switch to CLEAN. (See the “Using the
Controls” section.) The light will turn on, indicating that the
cleaning cycle is in process. When the indicator light turns off
(approximately 45 minutes), the cleaning cycle is complete.
During the cleaning cycle, the system will both clean and
rinse itself.
8.
After the cleaning cycle is complete, remove the drain cap
from the water pan to see if any cleaning solution is left in the
water pan. If cleaning solution drains from the water pan, you
should run the clean cycle again. Be sure to replace the drain
cap securely on the water pan. If the drain cap is loose, water
will empty from the water pan and you will have either thin ice
or no ice.
NOTE:
Severe scale buildup may require repeated cleaning with
a fresh quantity of cleaning solution.
9.
Push the selector switch to ON to resume ice production.
Condenser
A dirty or clogged condenser:
■
Prevents proper airflow.
■
Reduces ice making capacity.
■
Causes higher than recommended operating temperatures
which may lead to component failure.
1.
Unplug ice maker or disconnect power.
2.
Remove the two screws in the lower access panel and the
two screws from the base grille area of the front panel
support. Pull forward to remove the lower access panel.
3.
Pull the bottom forward and then pull down to remove the
lower access panel.
4.
Remove dirt and lint from the condenser fins and the unit
compartment with a brush attachment on a vacuum cleaner.
5.
Replace the lower access panel using the four screws.
6.
Plug in ice maker or reconnect power.
Interior Components
1.
Unplug ice maker or disconnect power.
2.
Open the storage bin door and remove any ice that is in the
bin.
3.
Remove the drain cap from the water pan and drain
thoroughly. Replace the drain cap securely on the water pan.
If the drain cap is loose, water will empty from the water pan,
and you will have either thin ice or no ice.
4.
Remove the three screws that hold the cutter grid cover in
place.
1. Water Pan
2. Drain Cap
2
1
1. Lower Access Panel Screws
2. Base Grille Screws
WARNING
Electrical Shock Hazard
Disconnect power before cleaning.
Failure to do so can result in death or
electrical shock.
Replace all panels before operating.