4-
REMOVING CAVITY THERMOSTAT #, THE MOTOR
CAPACITOR, THE AC LINE FILTER AND
THE POWER SUPPLY CORD
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug microwave oven or disconnect
power.
2. Remove the microwave oven from its
mounting location (see page 2-4 for the
procedure and reverse the procedure).
3. Remove the cabinet from the oven (see
page 4-4 for the procedure).
WARNING
Motor Capacitor
AC Line Filter
Power Supply Cord
Cavity Thermostat #1
4.
To remove cavity thermostat #:
a) Disconnect the two wire connectors
from the cavity thermostat terminals.
b) Remove the two cavity thermo-
stat bracket nuts and remove the
thermostat.
Cavity Thermostat #1
Wire Connectors
Bracket Nuts
5.
To remove the motor capacitor:
a) Discharge the capacitor by touching
the leads of a 20,000
Ω
resistor from
each of the capacitor leads to the
chassis ground.
b) Disconnect the two wire connectors
from the capacitor terminals.
c) Remove the capacitor screw and re-
move the capacitor.
Motor Capacitor
Screw
Connectors
YL
BR
Summary of Contents for KAC-48
Page 1: ...TECHNICAL EDUCATION JOB AID 4317414 KAC 48 MICROWAVE OVEN HOOD COMBINATION MODEL KHMS1850S ...
Page 48: ...4 28 NOTES ...
Page 65: ...7 NOTES ...
Page 66: ...7 NOTES ...
Page 68: ......