4-6
20. Lift the rear of the evaporator and the front
of the ice making component housing,
then slide the housing under the evapora-
tor toward the front of the unit until the
housing clears the evaporator.
21. Rotate the ice making component housing
so you can easily access the recirculation
pump mounting screws.
Ice Making Component Housing
Evaporator
22. Use a 9/32
″
socket or a phillips screw-
driver, and remove the recirculation pump
mounting screws.
23. Disconnect the end of the water inlet fill
tube from the recirculation pump and re-
move the pump.
3 Pump Screws
Rotate Housing Over Evaporator
Water Recirculation Pump
Water Inlet Fill Tube