4-14
REMOVING THE MASTER SWITCH, RECIRCULATION PUMP
MOTOR CAPACITOR, AND ELECTRONIC CONTROL BOARD
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1.
Unplug ice maker or disconnect power.
2.
Remove the screws from the lower front
panel and grille assembly and remove the
assembly.
4.
To remove the master switch:
a) Remove the hex nut w/boot from the
master switch.
Front Panel &
Grille Assembly
b) Disconnect the five wires from the mas-
ter switch terminals and remove the
switch from the enclosure. NOTE: If
necessary, see the switch wiring on
page 5-3.
Electronic Control Board Cover
Nut W/Boot
Cover Screw
Master Switch
3.
Remove the screw from the electronic
control board cover and remove the cover
(see the photo at the top of the next
column).