4-18
REMOVING THE CONDENSER
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1.
Unplug ice maker or disconnect power.
2.
Turn off the water supply to the ice maker.
3.
Move the ice maker to gain access to the
rear of the unit.
4.
Disconnect the drain outlet hose from the
ice maker.
5.
Disconnect the water inlet line from the ice
maker.
6.
Open the ice maker door.
7.
Remove the ice from the storage bin.
8.
Remove the screws from the lower front
panel and grille assembly and remove the
assembly.
9.
Remove the two screws from the con-
denser flanges.
10. Remove the two screws from the top con-
denser bracket.
Top Condenser Bracket Screws
11. Remove the six screws from the unit com-
partment cover, remove the cover, and
pull the power cord and strain relief out of
the u-channel.
Unit Compartment Cover
Screw (1 0f 6)
Front Panel & Grille Assembly
Condenser Flange Screws (1 of 2)
Power Cord & Strain Relief
Summary of Contents for KAR-13