5-4
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-14 for the procedure for servic-
ing the recirculation pump motor capacitor.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the R x 10K scale.
3.
Touch the ohmmeter test leads to the
capacitor terminals. The meter should
deflect momentarily, and then move to
infinity. To repeat the test, reverse the
ohmmeter test leads. The result should be
the same if the capacitor is good.
RECIRCULATION PUMP
MOTOR CAPACITOR
Refer to page 4-16 for the procedure for servic-
ing the condenser fan motor.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads to the pins
of the condenser fan motor 2-wire connec-
tor. The meter should indicate between 45
and 65
Ω
.
CONDENSER FAN MOTOR
Summary of Contents for KAR-13
Page 1: ...TECHNICAL EDUCATION JOB AID 4317309 KAR 13 OUTDOOR AUTOMATIC ICE MAKER Model KUIO15NNLS ...
Page 10: ...1 6 OUTDOOR ICE MAKER WARRANTY ...
Page 14: ...3 2 WATER AND REFRIGERANT CIRCUIT ...
Page 42: ...5 6 NOTES ...
Page 43: ...6 1 DIAGNOSIS TROUBLESHOOTING TIMING CHART ...
Page 52: ...8 4 NOTES ...
Page 53: ...8 5 NOTES ...
Page 54: ...8 6 NOTES ...
Page 56: ......