The cook top is designed to be built in to a work surface as shown in the figure.
Before installing the cook top, install the gasket seal
around the entire perimeter of the hole where it
will be inserted.
The dimensions of the hole are shown in figures 6-7-8-9.
For Filotop models, the perimeter of the hole must be lowered by a depth of 1.5 mm.
The hole does not need to be milled for Semifilotop models.
The cook top can be installed on different materials such as brickwork, steel, marble, conglomerates,
synthetics, wood and wood covered with plastic laminates, so long as resistant to a temperature of 90 °C.
x
Installation
11
If you are using a different kind of gas from the one
indicated on the serial no. plate and the orange
label on the back of the hob, you must replace the
injectors; in the case of the Wok burner, adjust the
primary air (see Injector table on page 7).
The orange label should be removed and kept
together with the manual.
Use pressure regulators suitable for the gas
pressures indicated on page 6
• In order to replace the injectors, contact the
Customer Care Centre on 00800-3810-4026,
or a qualified electrician.
• Injectors not supplied as standard should be
requested from the Customer Care Centre on
00800-3810-4026.
• Regulate the minimum levels of the taps.
Note: with liquid petroleum gas ( G30/G31)
the bypass screw must be screwed in fully. If
you then experiance difficulty in turning the
control knob, contact our After sales Service
though our Customer Care Centre on
00800-3810-4026, who will arrange for a
replacement after ascertaining that the tap is
damaged.
Adaption to a different type of gas supply
(*)
(*)
x
x
Sealing strip
Sealing strip
(*) Hob mounting bracket
without adapter extensions
for top thicknesses of 60
to 70 mm.
(*) Bracket with
adapter extensions:
- short for top
thicknesses of 50 to
70 mm.
- long for top
thicknesses of 30 to
50 mm.