background image

4

INSTALLATION INSTRUCTIONS

Remove Mounting Plate

NOTE: To avoid possible damage to the work surface, cover the 
work surface.
1. Remove any remaining contents from the microwave oven 

cavity.

2. Remove the mounting plate by peeling off the strips of tape 

that attach it to the back of the microwave oven, and set the 
mounting plate aside.

3. Tape the microwave oven door closed so that door does not 

swing open while the microwave oven is being handled.

NOTE: To avoid damage to the microwave oven, do not grip or 
use the door or door handle while the microwave oven is being 
handled.

Convert Microwave Oven to 

External Venting

(for wall or roof venting only)

The microwave oven is set for recirculation installation. For wall or 
roof venting, changes must be made to the venting system. See 
“Venting Design Specifications” section.
NOTE: Skip this section if you are using recirculation installation. 
Keep the damper assembly in case the venting method is 
changed, or the microwave oven is reinstalled in another location 
where wall or roof venting may be used.
To prepare the microwave oven for wall or roof venting, the vent 
deflector (L-shaped metal bar) must be installed, and the 
appropriate damper vent opening must be uncovered.

To Install Vent Deflector:

1. Gently pull the rings and lift vent screen from the top of the 

microwave oven.

2. With vent deflector oriented as shown (wide side down), slide 

it back and under the back edge of the vent opening.

A. Mounting plate
B. Back of microwave oven

C. Tape (multiple locations)

A                     B                         C

A. Top of microwave oven
B. Vent screen

C. Rings

A. Vent opening
B. Vent deflector

B                   C

A

A              B

Summary of Contents for KHMS2056SBL0

Page 1: ...e Wall Stud s 6 Mark Rear Wall 7 Drill Holes in Rear Wall 7 Attach Mounting Plate to Wall 8 Prepare Upper Cabinet 8 Install the Microwave Oven 9 Complete Installation 10 VENTING DESIGN SPECIFICATIONS 11 ASSISTANCE 12 Replacement Parts 12 W10117077 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell...

Page 2: ...th your builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damages For gas cooktop we recommend that combined cooking surface rating does not exceed 50 000 BTU hr The microwave oven is set for recirculation mode For external wall or roof venting see Venting Design Specifications section Special Requirements For Wall Venting Installation O...

Page 3: ...round prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the elect...

Page 4: ...ion For wall or roof venting changes must be made to the venting system See Venting Design Specifications section NOTE Skip this section if you are using recirculation installation Keep the damper assembly in case the venting method is changed or the microwave oven is reinstalled in another location where wall or roof venting may be used To prepare the microwave oven for wall or roof venting the v...

Page 5: ... 4 Position the damper assembly so that the long tab slides into the slot on the right side of the damper vent opening as shown Then secure with mounting screw Roof Venting Installation Only To Remove Roof Damper Vent Cover 1 Locate the roof damper vent cover on the top of the microwave oven 2 Using diagonal wire cutting pliers gently snip out the damper vent cover at the perforations 3 Save the c...

Page 6: ...e mounting plate No Wall Studs at Corner Holes Figure 1 No Wall Studs at Corner Holes Figure 2 NOTE If wall stud is within 6 15 2 cm of the vertical centerline see Mark Rear Wall section only recirculation or roof venting installation can be done Wall Stud at One Corner Hole Figure 3 Wall Studs at Both Corner Holes Figure 4 A Corner holes on mounting plate B Cabinet opening vertical centerline C W...

Page 7: ...omplete the 12 x 4 30 5 x 10 2 cm rectangle This is the venting cutout area 11 Cut a 3 4 19 mm hole in one corner of the cutout area 12 Using a keyhole saw cut out the venting cutout area DrillHolesinRear Wall In addition to being installed on at least 1 wall stud the mounting plate must attach to the wall at both bottom corner holes If the holes are not over wall studs use two 1 4 20 x 3 round he...

Page 8: ...ut to go through the wall and to open 3 Position mounting plate on the wall making sure that the top of the mounting plate is aligned with the front edge of the upper cabinet 4 Push the bolt with toggle nut through the drywall and finger tighten the bolt to make sure toggle nut has opened against drywall 5 Insert a lag screw into the remaining bottom corner hole 6 If installing on a second wall st...

Page 9: ...ave oven and hang it on support tabs at the bottom of mounting plate NOTE To avoid damage to the microwave oven do not grip or use the door or door handle while the microwave oven is being handled 4 With front of microwave oven still tilted thread power supply cord through the power supply cord hole in the bottom of the upper cabinet 5 Rotate microwave oven up toward upper cabinet NOTE If venting ...

Page 10: ...eteInstallation 1 Refer to the Use and Care Guide for instructions on how to install filters into your model 2 Plug microwave oven into grounded 3 prong outlet 3 Reconnect power 4 Check the operation of microwave oven by placing 1 cup 250 mL of water on the turntable and programming a cook time of 1 minute at 100 power Test vent fan and exhaust by operating the vent fan 5 If the microwave oven doe...

Page 11: ...amper to open fully If venting through the roof and rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the microwave oven and the transition piece See Rectangular to Round Transition illustration Rectangular to Round Transition NOTE The minimum 3 7 6 cm clearance must exist between the top of the microwave oven and the rectangular to round tr...

Page 12: ... microwave oven model number and serial number Both numbers can be found on the model and serial number plate which is located behind the microwave oven door on the front frame of the microwave oven If you need additional assistance call us at our toll free number listed in the Use and Care Guide or visit us on the Web ReplacementParts If any of the installation hardware needs to be replaced call ...