Note: Refer to the injector table to ensure the correct type of
injector is to be fitted.
Traditional burners (T)
1. Remove the pan supports (A).
2. Remove the burners (B).
3. Unscrew the injector (C) with a no 7 box spanner.
4. Replace the injector with one suitable for the new gas type.
5. Replace burners and pan supports.
Note: Before installing the hob, please remember to stick the gas
calibration label, provided with the replacement injectors over the
gas information on the underside of the hob.
Wok Burner (W)
It is best to change the wok double crown burner before starting
installation:
1. Lift out the hob from the work surface, removing the installation
fixing pieces.
2. Remove the screws securing the glass, at the back of the hob plate
and those located on both sides of the hob (E).
3. Remove the holding screws that fix the burner to the glass hob.
Once you have removed the glass hob, you can access the wok
burner injector.
4. Remove the injector (F) using a 10mm spanner.
5. Slacken the holding screw (H) to regulate the position (X) of the
gas inlet coupling (G) with regard to the injector.
Replacing the injectors
If you are using a different kind of gas from the one
indicated on the serial no. plate and the orange
label on the back of the hob, you must replace the
injectors; in the case of the Wok burner, adjust the
primary air (see Injector table on page 6).
The orange label should be removed and kept
together with the manual.
Use pressure regulators suitable for the gas
pressures indicated on page 6
• In order to replace the injectors, contact the
Customer Care Centre on 00800-3810-4026,
or a qualified electrician.
• Injectors not supplied as standard should be
requested from the Customer Care Centre on
00800-3810-4026.
• Regulate the minimum levels of the taps.
Note: with liquid petroleum gas ( G30/G31)
the bypass screw must be screwed in fully. If
you then experiance difficulty in turning the
control knob, contact our After sales Service
though our Customer Care Centre on
00800-3810-4026, who will arrange for a
replacement after ascertaining that the tap is
damaged.
Adaption to a different type of gas supply
12
Summary of Contents for KHPF 9010
Page 1: ...KHPF 9010 KHPS 9010 ...
Page 2: ......