20
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14
ʺ
(36 cm) water
column.
Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This range is factory-set for use with Natural gas. To use this
range with Propane gas, see the “Gas Conversions” section
before connecting this range to the gas supply. Gas conversions
from Natural gas to Propane gas or from Propane gas to Natural
gas must be done by a qualified installer.
Typical Flexible Connection
1.
Apply pipe-joint compound made for use with Propane gas to
the smaller thread ends of the flexible connector adapters.
See B and G in the following illustration.
2.
Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters,
being certain not to move or turn the gas pressure regulator.
3.
Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the flexible connector to the adapters.
IMPORTANT:
All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause a
gas leak. Do not allow the regulator to turn when tightening
fittings.
A.
1/2" (1.3 cm) or 3/4" (1.9 cm)
gas pipe
B.
Use pipe-joint compound
C. Adapter
D. Manual gas shutoff valve
E.
Flexible connector
F.
Adapter (must have 1/2" [1.3
cm] male pipe thread)
G. Use pipe-joint compound
H. Gas pressure regulator
Complete Connection
1.
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed Valve
B. Open Valve
2.
Test all connections by brushing on an approved noncorrosive
leak-detection solution. If bubbles appear, a leak is indicated.
Correct any leak found.
3.
Remove cooktop burner caps and bases from package
containing parts. Place the burner bases as indicated below:
A.
Small (Auxiliary)
B.
X-Large (Stack)
C. Oval (OV)
D. Medium (Semi
Rapid)
E.
Large (Ultra
Rapid)
NOTE:
Each round burner base is marked with one of the
following: AUX, SR, UR, or ST.
4.
Align the gas tube opening in the burner base with the orifice
holder on the cooktop and the igniter electrode with the notch
in the burner base.
A. Burner cap
B. Gas tube opening
C. Burner base
D. Igniter electrode
E. Orifice holder