28
Complete Installation
1.
Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2.
Check that you have all of your tools.
3.
Check that you have all of the range accessories, especially
oven racks. These accessories may be in the range
packaging.
4.
Dispose of/recycle all packaging materials.
5.
Check that the range is level. See the “Level Range” section.
6.
Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by shipping material.
Dry thoroughly with a soft cloth. For more information, see the
“Range Maintenance and Care” section.
7.
Read the Quick Start Guide and online Control Guide.
8.
Turn on surface burners and oven. See the Quick Start Guide
and online Control Guide for specific instructions on range
operation.
NOTE:
Odors and smoke are normal when the oven is used
the first few times.
If Range Does Not Operate, Check the Following:
�
Household fuse is intact and tight, or circuit breaker has
not tripped.
�
Gas pressure regulator shutoff valve is in the open
position.
�
Range is plugged into a grounded outlet.
�
Electrical supply is connected.
IMPORTANT:
If the range control displays an “F9” or “F9,
E0” error code, the electrical outlet in the home may be
miswired. Disconnect power and contact a qualified
electrician to verify the electrical supply.
9.
When the range has been on for 5 minutes, check for heat. If
the range is cold, turn off the range and check that the gas
supply line shutoff valve is open.
�
If the gas supply line shutoff valve is closed, open it, and
then repeat the 5 minute test as outlined above.
�
If the gas supply line shutoff valve is open, close it, and
contact a qualified technician.
If You Need Assistance or Service:
Please refer the Quick Start Guide for contact information.
GAS CONVERSIONS
Gas conversions from Natural gas to propane gas or from
propane gas to Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14
ʺ
(36 cm) water
column.
Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING:
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of
the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, an
explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is
checked as specified in the manufacturer’s instructions
supplied with the kit.
Summary of Contents for KSDG950ESS
Page 70: ...REMARQUES ...
Page 71: ...REMARQUES ...