15
Vacation and Moving Care
To shut down the ice maker:
1. Unplug ice maker or disconnect power.
2. Remove all ice from storage bin.
3. Shut off the water supply.
4. Remove the two screws in the lower access panel and
the two screws from the base grille area of the front
panel support. Pull forward to remove the lower access
panel.
5. Disconnect the inlet and outlet lines to water valve.
Allow these lines to drain and then reconnect to the
valve.
6. Replace lower access panel and screws.
7. Drain water from water pan by removing the drain cap.
8. If the room temperature will drop below 32° F (0° C),
remove water from the drain line.
For ice makers with a drain pump installed:
a) Plug in ice maker or reconnect power.
b) Turn ice maker off and remove all remaining ice from
ice bin.
c) Pour 1 quart (0.95 L) of water into the ice bin near
the drain and let the unit stand for approximately
five minutes. This will allow the water in the bin to
drain into the drain pump so that the pump will
remove the remaining water from the ice bin and the
drain pump.
d) Unplug ice maker or disconnect power.
9. Before using again, clean the ice maker and storage
bin.
10. Plug in ice maker or reconnect power.
NOTE: All components of the ice maker are permanently
lubricated at the factory. They should not require any
additional oiling throughout the normal life of the machine.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all panels before operating.
Summary of Contents for KUIS155HLS0