12
4.
Use UL listed wire connectors and connect the white wires
(D) together.
5.
Use UL listed wire connectors and connect the red wires (E)
together.
6.
Use UL listed wire connectors and connect the blue wires (F)
together.
7.
Use UL listed wire connectors and connect the gray wires
(G) together.
8.
Connect the green (or yellow/green) ground wire to the
green/yellow ground wire (H) in the terminal box using UL
listed wire connectors.
9.
Reinstall the in-line blower terminal box cover and screw.
10.
Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical Connection Inside Range Hood Between
In-line Blower System and Range Hood
1.
With the range hood mounted (see the “Install Range Hood”
section), locate the wiring cable connector inside the range
hood.
2.
Connect the 6-wire connector assembly supplied with the
in-line blower motor system to the mating cable connector
from the range hood.
3.
Locate the terminal box inside the range hood and install
a 1/2" (1.3 cm) UL listed or CSA approved strain relief
(see
“Complete Preparation” in the “Prepare Location”
section).
4.
Run the wire ends from the 6-wire connector assembly
through the 1/2" (1.3 cm) strain relief, leaving enough wire
length to make the wiring connections. Tighten the strain
relief screws.
5.
Connect the wires from the 6-wire connector assembly to
the wires from the wiring conduit inside the range hood
terminal box.
6.
Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE:
Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors (see the
“Make Electrical Power Supply Connections to Range Hood”
section).
7.
Go to “Make Electrical Power Supply Connection to Range
Hood” section.
Make Electrical Power Supply
Connection to Range Hood
1.
Disconnect power.
2.
Locate terminal box inside of the range hood.
WARNING
Electrical
S
hock Hazard
Electrically
g
round blower.
Connect
g
round wire to
g
reen and yellow
g
round wire
in terminal box.
Failure to do
s
o can re
s
ult in death or electrical
s
hock.
A
B
C
D
E
F
G
H
I
A. UL listed or CSA approved
1/2" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow) wire
I. 6-wire connector assembly
WARNING
Electrical
S
hock Hazard
Di
s
connect power before
s
ervicin
g
.
Failure to do
s
o can re
s
ult in death or electrical
s
hock.
Replace all part
s
and panel
s
before operatin
g
.
B
A
A. Terminal box cover
B. Knockout in back into terminal box