background image

2

WARNING: If the information in this manual is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this 
or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's 
instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or 
the gas supplier.

WARNING: 

Gas leaks cannot always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.

For more information, contact your gas supplier.

If a gas leak is detected, follow the “What to do if you smell gas” instructions.

In the State of Massachusetts, the following installation instructions apply:

■  

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by 

the State of Massachusetts.

■  

If using a ball valve, it shall be a T-handle type.

■  

A flexible gas connector, when used, must not exceed 3 feet.

Summary of Contents for LP

Page 1: ...u don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always ...

Page 2: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions In the State...

Page 3: ...quirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appli...

Page 4: ...urface Burners 1 If installed remove the burner grates Use the following figures to match the correct LP gas orifice spud with the burner location and model being converted The orifice spud size is stamped on the orifice spud as shown below This number codes the orifice diameter and its correct burner location 4 Burner Models LP Gas Orifice Spud Chart 2 Remove burner caps 3 Using a 20 Torx screwdr...

Page 5: ...ner is used or when adjustments are made to the flame length To Adjust This cooktop is shipped from the factory with low and high flame settings adjusted for use with Natural gas To set for use with LP gas proceed as follows 1 Light 1 burner and turn to lowest setting 2 Remove the control knob 3 Remove grommet from glass 4 Use an 3 0 mm flat blade screwdriver to turn the screw located to the right...

Page 6: ...in excess of psi 3 5 kPa Line pressure testing at psi gauge 14 WCP or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa To Convert Surface Burners 1 If they are installed remove the burner grates Use the following figures ...

Page 7: ...for leaks by brushing on an approved noncorrosive leak detection solution If bubbles appear a leak is indicated Correct any leaks found 13 Plug in cooktop or reconnect power FlameHeightAdjustment Smart Port Burner System This cooktop is equipped with a Smart Port Burner System The Smart Port Burner System produces a small flame directly under each grate finger and a larger flame between each grate...

Page 8: ...do not light properly turn the control knob to the OFF position Make sure the burner cap is in the proper position 3 Check that the power supply cord is plugged in Check that the circuit breaker has not tripped or the household fuse has not blown 4 Check that the manual shutoff valve is in the open position 5 Check burner operation again If one or all of the burners do not light at this point see ...

Page 9: ...ce ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du téléphone d un voisin Suivre ses instructions À défa...

Page 10: ...tionnelles Si les présentes instructions ne sont pas rigoureusement respectées ceci peut provoquer un incendie une explosion ou la génération de monoxyde de carbone provoquant des dommages corporels ou matériels ou même la mort La responsabilité de l installation correcte de cet ensemble de conversion incombe au personnel qualifié d une agence de service L installation n est pas correcte et complè...

Page 11: ... La table de cuisson devra être isolée des canalisations d alimentation en gaz par la fermeture du robinet d arrêt manuel individuel durant tout test de pressurisation des canalisations d alimentation en gaz à une pression égale ou inférieure à lb po 3 5 kPa Conversion des brûleurs de surface 1 Enlever les grilles de brûleur si elles sont installées Dans les schémas qui suivent choisir le gicleur ...

Page 12: ...e l électrode traverse sans difficulté le trou dans la base du brûleur 10 Réinstaller le chapeau de brûleur 11 Répéter les étapes 2 à 10 pour les autres brûleurs 12 Ouvrir le robinet d arrêt de la canalisation de gaz Le robinet est ouvert lorsque la manette est parallèle à la canalisation de gaz NE PAS OUBLIER Après avoir exécuté la conversion de chaque brûleur de la table de cuisson effectuer un ...

Page 13: ...rel 1 Fermer le robinet d arrêt manuel 2 Débrancher la table de cuisson ou déconnecter la source de courant électrique Conversion du détendeur 1 Utiliser une clé pour enlever le chapeau de l ouverture d accès faire tourner le chapeau dans le sens antihoraire Ôter le ressort de retenue qui se trouve sous le chapeau pousser contre le côté plat du ressort de retenue Examiner le ressort de retenue pou...

Page 14: ...ne seule base de brûleur à la fois Réinstaller la base après la conversion du brûleur Ne pas démonter la totalité de la table de cuisson 5 Appliquer du ruban adhésif de masquage à l extrémité d un tourne écrou de 7 mm pour retenir le gicleur du brûleur dans le tourne écrou durant l extraction Placer le tourne écrou sur le gicleur faire tourner dans le sens antihoraire et soulever pour enlever le g...

Page 15: ...1 à 7 pour chaque brûleur Allumagedubrûleuretsystèmederallumage automatique Cette table de cuisson est équipée pour le rallumage électronique déclenché par un allumeur situé à l arrière de chaque brûleur Les brûleurs sont conçus pour s allumer à n importe quelle rotation de robinet qui permet un débit de gaz suffisant pour soutenir une flamme et se rallumer automatiquement suite à une perte de fla...

Page 16: ...erver les gicleurs qui ont été retirés de la table de cuisson avec les présentes instructions pour utilisation ultérieure 4 Lire la section Brûleurs de surface scellés dans le Guide d utilisation et d entretien fourni avec la table de cuisson A Débit thermique minimum B Débit thermique maximum A B W10299785A 2009 All rights reserved Tous droits réservés Registered Trademark TM Trademark of Kitchen...

Reviews: