8. Troubleshooting
Issue
Description
Action
Electric box failure due to short-
circuit or equipment needing too
much power
Electric box in protection mode
Disconnect all equipment and
reconnect
The automatic control of the
servomotor does not work
The force required to rotate the
mechanism is too high
Try to unstuck it manually
The rope belt rubs on guides
(generator)
The generator tilts on one side
The traction of the kite is
insufficient, the flight angle is too
low
Check that the crank is correctly
positioned on the smooth side of
the reel
Check that the command and
power cables do not unbalance
the generator
The kite cannot lift the wind
turbine
The wind is too weak
Try to increase the distance
between the kite and the wind
turbine by attaching the omega
lower on the safety line
The kite is not stable in strong
winds
The geometry of the kite does not
allow stability in very powerful
wind, it is necessary to add a tail
Attach the kite storage bag to
the back of the kite (tail)
The rotation of the blades does
not start
Not enough wind
Not enough battery for automatic
start of the blades rotation
Wait for the wind to become
sufficient
Manually start the propeller
with the rope belt
Charging the battery
Blades are rotating but no
electricity is produced
Mechanical transmission
problem or electric problem
Battery too low
Check the bearings
Check that the rope belt is in the
tread on the generator and on
the wind turbine
Check the position and the wear
of the toothed belt
Check fuse
Check connections
Wait for charge
Abnormal noise from the
generator
Item loose or touching a rotating
part
Check the tightness of the
screws
Check the position of the locking
tab, in production mode, slightly
changing its position can make
the problem disappear
Please contact us for any other issue.