SU 120417

Summary of Contents for KF-35B

Page 1: ...SU 120417 ...

Page 2: ...he boiler after reading it The user s manual describes the features of the product and the safety requirements Please read and make sure you fully understand the user s manual before using the products to ensure an extended lifecycle User s Manual Kiturami Firewood Boiler ...

Page 3: ... 03 04 07 09 09 14 15 16 18 Hazard or unsafe practices that may result in severe personal injury or death Hazard or unsafe practices that may result in severe personal injury or death To reduse the risk of fire explosion electric shock or personal injury when using boiler please refer to the manual carefully Precautions for Safety The user s manual uses symbols to indicate that caution should be e...

Page 4: ...er cover Handle movement Controller Automatic air control Hot water inlet Heating water outlet Hot water outlet Controller cover Back of flue cleaning port Heating water collection Controller cover Front Right Included accessories The KF 35B User s Manual cleaning tools and corrugated drain pipe ...

Page 5: ...on lamp This lamp is turned on when the boiler exhaust fan works Circulation pump lamp The water is being circulated Low water level lamp The water is insufficient in the boiler Season selection button You can set the heating water temperature You can set the preferred temperature Power S N Boiler operation switch ON OFF ...

Page 6: ...LED flashes If the Option function works display of the operation Flash of LED in case of a boiler abnormality check Operation at set temperature Initial mode Option function Heating water temperature setting function Water temperature is maintained at 83 C adjustable Automatic return to heating function after 2 5 hours Option function Hot water temperature setting function Manual return restart i...

Page 7: ...uous combustion is possible through adding more firewood as soon as wood is lit When inserting the firewood Insert wood in a good size enough to close the wood hatch completely Put the Tinder in the central part of the firebox add the firewood and light the Beongaetan using papers etc Keep the ashtray hole open until the firewood is ignited to a certain level When the firewood is completely lit cl...

Page 8: ... frozen rupture and disconnect the power cable from the outlet The exposed pipes should be wrapped with an insulator 25mm thick or more to prevent the pipes from freezing 50 mm or more in cold areas f you leave your home for a number of hours open the hot water tap in the kitchen slightly to allow a small volume of water to flow into the hot water pipe to prevent a frozen rupture of the tap water ...

Page 9: ...g closing the wood hatch be careful to not burn your self When opening the wood hatch open the door in a lateral direction in order to avoid possible heat burns After adding firewood tightly close the inlet The sparks may cause a fire in the surroundings area As sparks may be dispersed resulting in a fire during the time to treat the ash clean the product after the complete removal of embers Cauti...

Page 10: ...and the CH area Install the boiler in a location such that exhaust gas or noise from the boiler does not cause inconvenience to the users or to residents in the vicinity of the boiler s location Do not install the boiler in a location adjacent to areas frequently accessed by people such as a staircase or emergency exit Secure sufficient space for the operation inspection and repair of the boiler 1...

Page 11: ...revent the stovepipe from contact with combustible materials Otherwise fire may breakout Finish the contact points with an incombustible insulation material when installing the flue to prevent fire Drainage of boiler If the capacity of the boiler is deficient for the heating area the safety valve may open often Install a nitrogen tank suitable for the capacity Overflow Connect hoses from the safet...

Page 12: ...y shutdown may be triggered causing abnormal operation of the boiler To prevent this the flue should be installed in a position outside the wind pressure zone Especially when you use wood or coal fuel you should avoid the wind pressure band FLUE Drainage device Install the device with inclination of 5 degrees 3M 1M T pipe Drainage device 1M or longer 1M or longer Shorter than 1M Drainage device 1M...

Page 13: ...supply Water supply Back side of the product Back side of the product Back side of the product Back side of the product Water supply pipe Water supply pipe Expansion tank Heating exit Safety valve Heating exit Air vent Nitrogen tank Above 20L Circulation pump Circulation pump Hotwater inlet Hotwater inlet Hot water outlet Hot water outlet Pressure gauge Distributor Distributor Above 3M Above 3M ...

Page 14: ... ex 1 ex 2 BOILER BOILER ex 1 ex 2 VALVE VALVE VALVE VALVE BOILER BOILER ex 1 ex 2 SUPPLEMENT WATER SUPPLEMENT WATER WARNING Please install the expansion tank 1m higher than from the top of the boiler DO NOT use valve at the fall pipe or expansion tank pipe Supply water pipe should be directly connected with expansion tank ...

Page 15: ...ng signals may become unstable resulting in operation trouble Also if the cable coating is aged due to the passage of time electric leakage or a short may be caused Attaching loop UP Canle outlet Scew in the anchoring parts Attaching loop DOWN Red White Wall Checkpoints after Installation Do the pipe parts not show any signs of leaking Is the boiler installed horizontally and parallel with the bot...

Page 16: ...AC 230V x 50Hz Remarks KF 35B Item Model Fuel feeding quantity kg Heating area m2 Heating efficiency Hot water efficiency Max service pressure kg cm2 Heating inlet outlet A Irrigation capacity liter Safety function Overheating shutdown function and overheating prevention function Low level function Freeze rupture prevention function Air processing function for initial test operation Constant tempe...

Page 17: ...e properly connected In many cases the driving part of the boiler circulation pump has a problem Check the heating pipes for the existence of air and deaerate the pipes if required The combustion sound is loud The flue is not adequately installed or is not thermally insulated Correct the installation of the flue or thermally insulate the flue If the abnormality continues contact a local distributo...

Page 18: ...ck the connector for wrong contact Contact a local distributor or A S center Water flows out of the fire chamber or combustion pipe This is a natural phenomenon where the water is condensed due to the difference in temperatures if you light the firewood in the state where the heating temperature is low and this condensation phenomenon disappears when the temperature rises Water may gather with con...

Page 19: ...MEMO 18 ...

Page 20: ...19 MEMO ...