55
Table 1.0 Command ID
Data Byte
Data Type
Byte details
7 ------- 0
Data Details
$63 (99) Arp Clock Divide
0000yyyy
yyyy=
0000-Half Note (48 Clocks/Step)
0001-Quarter note (24 Clocks/Step)
0010-8th note (12 Clocks/Step)
0011-8th note, half swing (14,10 Clocks/Step)
0100-8th note, full swing (16,8 Clocks/Step)
0101-8th note triplets (8 Clocks/Step)
0110-16th note (6 Clocks/Step)
0111-16th note, half swing (7,5 Clocks/Step)
1000-16th note, full swing (8,4 Clocks/Step)
1001-16th note triplets (4 Clocks/Step)
1010-32nd note (3 Clocks/Step)
1011-32nd note triplets (2 Clocks/Step)
1100-64th note triplets (1 Clocks/Step)
Clock source is Master Clock
$64 (100) Seq Control
000vwxyz
z =
Reserved
y =
KeyDownPlay (0=Seq always plays when enabled,
1=Seq only plays when enabled AND a Key is
being held down)
x =
AutoTranspose (0=actual seq notes,1=transpose
last played)
w =
AutoTransposeReset (0=continue seq in new
transpose, 1=reset seq to step 1 on new
transpose value)
v =
Reserved
$65 (101) Seq Transpose
0-36
0-36 (-1 oct -> +2 Octs) - only used if SeqControl Bit
2 set
$66 (102) Dynamics Control
0000yyzz
zz =
VCF Cutoff Enable(0-3)
yy =
VCA Amount Enable(0-3) 0=off,1=30%,2=60%,3=100%
www.kiwitechnics.com
Kiwi-106 Upgrade User Manual v204