• Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
• An air supply / extractor box alone does not ensure compliance with the limit value.
Safe operation is only possible when the negative pressure in the room where the appliance is located does
not exceed 4 Pa (0.04 mbar). This can be achieved when the air required for combustion can flow through
openings that are not closable, for example in doors, windows, in conjunction with an air supply / extractor box
or through other technical measures. In any case, consult a qualified chimney sweep who can assess the entire
ventilation of your house and propose appropriate measures for adequate ventilation.
If the hood is used exclusively in the recirculation mode, unrestricted operation is possible.
WARNING
Fire hazard from flying sparks. Only install equipment on a fireplace for solid fuels (for ex-
ample, wood or coal), if a closed, non-removable cover is available.
Control Panel and Controls
Control Panel
Controls and Functions
ON/OFF button
Touch this button to turn the motor on/off.
Speed increase button
Touch this button to increase speed.
Speed decrease button
Touch this button to decrease speed.
Light button
Touch this button to turn the light on/off.
Summary of Contents for 10031680
Page 1: ...10031680 10032292 10032293 10032294 Dunstabzugshaube ...
Page 4: ...4 Klammern und Haken Schornsteinhalterung Schornsteinhalterung Haken Abmessungen ...
Page 10: ...10 Brackets and Hook Chimney bracket Chimney bracket Hook Dimensions ...
Page 16: ...16 Staffe e gancio staffa camino staffa camino gancio Dimensioni ...
Page 22: ...22 Soportes y gancho soporte de la chimenea soporte de la chimenea gancho Dimensiones ...
Page 28: ...28 Supports et crochets support de cheminée support de cheminée crochet Dimensions ...