21
EN
TROUBLESHOOTING
Please note, if the water filled to the evaporator is not symmetrical, small sundries
maybe be formed and lod- ged in the pipe which will mean that water will be filled to
the evaporator causing it to jam. Please pull out the cap of the pipe, then let the water
through the pipe in order to clean the pipe, then you can replace the cap. It will make
formal ice cubes.
Problem
Possible Cause
Solution
The compressor works
abnormally with a buzzing
noise.
The voltage is lower than
recommended.
Stop the Ice maker and do
not restart until the voltage
is normal.
The light of ADD WATER
is on.
There is no water or water
is not enough.
Press the “STOP” button,
fill with water, and press
the “START” button again
to restart.
Indicator light on the
display is not on.
Control panel wire line is
loosen.
Call for service.
Control panel is broken.
The water is flowing,ice is
made,however no release
of ice.
Temperature sensors are
connected by mitake.
Call for service.
Everything is correct but
no ice is made.
Refrigerant leaks.
Call for service.
Cooling system blocked.
Spray pipe jammed.
Step 1: Take down the spray pipe from the evaporator.
Step 2: Take off the pipe plug from the spray pipe.
Step 3: Let water flow from the pipe for a while. Fix the
spray pipe from step 3 to step 1.