Unpacking
Check that the rangehood is not damaged.
Transportation damages should immediately be
reported to the transport company. Damages, faults
and missing parts should immediately be reported
to the retailer.
Dispose carefully of the packaging material so that
it is out of the way of small children.
Position
The rangehood should be mounted freely hanging
on the wall. The rangehood must be at least 650mm
from the cooking plane for electric, gas and mixed
cooktops. The recommended distance for canopy or
island is 750mm. Please confirm this measurement
with your Local Building Authority. The rangehood
can be installed above these heights but for
optimum performance it should be installed at the
distance quoted.
The rangehood cannot be connected to
flues of other appliances that run on
energy sources other than electricity.
Please, keep to the provisions of official
directives regarding fume discharge.
Electrical connection
The rangehood has a power cable with earth
connection and the rated voltage is 220-240V.
Assembling the chimney flue support/bracket (3
parts):
The three parts should be fixed with 4 screws, the
support extension is adjustable and should
correspond to the internal width of the telescopic
chimney flue.
Installation
=
=
X
X
Fig. 6
Changing the light bulb
Disconnect the unit from the mains power supply.
Firstly check that the lamps are well cooled prior to
replacing them.
Access the light compartment extract the guard by
levering it off with a small screwdriver or similar tool.
Replace the old bulb with a new one of the same type.
Use 20W (G4) bulb only.
Close the lamp cover (it will snap shut).
If the light does not come on, make sure the bulb has
been inserted correctly before contacting your authorised
Kleenmaid Service Agent.