ENGLISH
fEATURE DETAILS
MM5000
Instruction Manual
GENERAL SPECIfICATIONS
The Klein Tools MM5000 is an auto-ranging multimeter. It measures AC/DC
voltage, low impedance voltage, AC/DC current and resistance. It can also
test diodes and continuity.
•
Operating Altitude: 6,562 ft. / 2,000 m
•
Relative Humidity: <75%
•
Operating Temperature: 32°F to 113°F (0°C to 45°C)
•
Storage Temperature: -4°F to 140°F (-20°C to 60°C ) <80% R.H.
•
Accuracy Temperature: 18°C to 28°C ( 64°F to 82°F)
•
Temperature Coefficient: 0.1*(specified accuracy)/ °C
•
Sampling frequency: 3 samples per second
•
Dimensions: 7” x 3.5” x 1.875” (178 x 89 x 48 mm)
•
Weight: 14 oz. (397 g)
•
Battery Life: 160 Hours
•
Drop Protection: 3 m
•
Ingress Protection: 40
•
Calibration: Accurate for one year
•
Accuracy: ± (% of r # of least significant digits)
•
Safety Rating: CAT III 1000V, CAT IV 600V
•
Certifications: Conforms to UL Stds 61010-1 & 61010-2-030.
Certified to CAN/CSA C22.2 No.61010-1, 61010-2-030,
IEC 61010-2-030:2010 MOD, ANSI/ISA-61010-2-030 (82.02.03).
•
Pollution Degree: 2
•
Country of Origin: USA (of US and imported parts)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring a known
voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
• Do not open the meter to replace batteries or fuses while the probes
are connected.
• Use caution when working with voltages above 60V DC or 25V AC
RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace
batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out power
before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
SYMBOLS
~
AC Alternating Current
Warning or Caution
DC Direct Current
Dangerous Levels
DC/AC Voltage or Current
Double Insulated Class II
Ground
AC Source
A.
DO NOT attempt to measure more than 1000V.
B.
DO NOT attempt to measure more than 600V on (LOW Z) setting.
C.
Select functionality Button
• Switch between AC and DC.
• Wake meter during Auto Power Off.
D.
Auto Hold
• Hold captures the current displayed value.
• Auto Hold captures the first stable displayed value, until a new
stable value is measured. The meter will then capture the new value
and emit a beep (V, Ohm and Amp functions).
• Press to hold current input on the display.
• Press again to enter Auto-Hold to capture stable values.
• Press again to return to normal operation.
E.
Auto / Manual Range
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
• AT is displayed on LCD only during auto ranging mode.
f.
Max / Min
• Press to enter Max/Min mode; the largest and smallest values will
be saved while in this mode.
• Press repeatedly to alternate between the maximum and minimum
readings.
• Press for 2 seconds to return to live reading and clear the stored
maximum and minimum values.
G.
Auto Power-Off (Apo)
• Device will power off after 30 minutes non-use.
• Press the select button to wake.
• Disabled during Max/Min function.
• Holding Select button while turning on disables Auto Power-Off.
H, I. Battery / fuse Replacement
• When
indicator is displayed on the LCD, batteries must be
replaced.
• Remove rubber boot, back screw and replace 2 x AAA batteries.
J.
Backlight
• Press to activate display backlight.
• Using lights drains the battery significantly.
K.
Bar Graph
• The bar graph shows an approximate analog representation
of a measurement.
• The bar graph responds much faster than the digital display.
• The scale of the bar graph is zero to the maximum reading of
the selected range.
L.
Magnetic Hanger Accessory (optional, sold separately) (69190)
• Slide magnetic adapter into protective rubber boot.
• Attach instruments to metal for hands-free use.
fUNCTION INSTRUCTIONS
1.
AC Voltage: <1000V. (LOW Z) < 600V
Features:
HOLD
AUTO HOLD
RANGE
MAX/MIN
DO NOT attempt to measure more than 1000V.
DO NOT use (LOW Z) mode at voltages greater than 600V.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "AC" Voltage position.
• Attach RED lead to “V” input.
3.
Resistance
Features:
HOLD
AUTO HOLD
RANGE
MAX/MIN
DO NOT attempt to measure more than 1000V.
DO NOT use (LOW Z) mode at voltages greater than 600V.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "DC" Voltage position.
• Attach RED lead to “V” input.
A
B
C
D
E
f
G
H
I
K
L
J
3
1
4
5
7
2
6
DO NOT measure resistance on a live circuit.
•
Ω
= < 40M
Ω
.
SYMBOLS USED ON LCD
~
AC Measurement
DC Measurement
-
Negative DC Value
AT
Auto Range Active
O.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
MAX
Maximum Reading
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in Ohms
Diode Test
Continuity Test
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
A- HOLD
Auto-Hold Active
LOW
Z
Low Impedance
2.
DC Voltage: <1000V. (LOW Z) < 600V
Features:
HOLD
AUTO HOLD
RANGE
MAX/MIN
Dwg Name:
MM5000-139749ART
Dwg No:
139749
ECO No:
016671
Pkg Dwg Ref:
1650
Rev:
B
Color Reference:
CEN-PACK-003-A
MM5000-139749-Instructions.indd 5-8
5/5/14 10:14 AM