Dwg Name:
MM700-1390112ART
Dwg No:
1390112
ECO No:
20617
Rev:
E
Pkg Dwg Ref:
1290186
Color Reference:
N/A
4
electrical SpecificationS
otHer MeaSureMent applicationS
Maximum input:
100V RMS in Voltage setting,
600V DC or 600V AC RMS in all other settings
•
Diode test:
1.5 mA max, open circuit voltage 3.0V DC
•
continuity check:
Audible signal when resistance <50Ω,
max test current 0.35mA
•
low impedence (low Z):
Input impedence >3kΩ
Max input 600V RMS
•
auto power off:
After ~30 minutes of inactivity
•
Sampling frequency:
3 samples per second
•
Bar Graph:
41 segment, 10-15 samples per second
•
overload:
"OL" indicated on display, 1000V RMS in voltage
settings, 600V RMS in all other settings
•
polarity:
"-" on display indicates negative polarity
•
Display:
3 ¾ digit, 4000 Count LCD, TRMS technology
electrical SpecificationS
capacitance (auto-ranGinG)
range
resolution
accuracy
40.00nF
10pF
±(5.0% + 35 digits)
400.0nF
0.1nF
±(3.0% + 5 digits)
4.000μF
1nF
40.00μF
10nF
400.0μF
100nF
4000μF
1μF
±(5.0% + 5 digits)
Maximum input:
600V DC or 600V AC RMS
frequency (auto-ranGinG)
9.999Hz
0.001Hz
±(1.0% + 5 digits)
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999kHz
1Hz
99.99kHz
10Hz
500.0kHz
100Hz
Sensitivity:
>8V RMS
Maximum input:
600V DC or 600V AC RMS
Duty cycle
1% to 99.9%
0.1%
±(1.2% + 2 digits)
pulse width:
0.1 – 100ms
frequency width:
5Hz to 10kHz
Sensitivity:
>8V RMS
Maximum input:
600V DC or 600V AC RMS
teMperature
0
°
to 1500
°
F
0.1°F / 1°F
±(2.0% + 9°F)
-18° to 816°C
0.1°C / 1°C
±(2.0% + 5°C)
enGliSH
WarninGS
to ensure safe operation and service of the meter, follow these
instructions. failure to observe these warnings can result in
severe injury or death.
• Before each use verify meter operation by measuring a known
voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT IV rated test leads.
• Ensure meter leads are fully seated, and keep fingers away
from the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes
are connected.
• Use caution when working with voltages above 25V AC RMS
or 60V DC. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock,
replace batteries when a low battery indicator appears.
• Do not attempt to measure resistance or continuity on a live
circuit.
• Always adhere to local and national safety codes. Use personal
protective equipment to prevent shock and arc blast injury
where hazardous live conductors are exposed.
• Meter is IP42 dust & water resistant. Following any contact
with water, thoroughly dry meter and test lead jacks prior to
subsequent use.
MM700-1390112ART.indd 4