background image

The VDV Commander features a full-color graphic LCD screen. 

Press any of the four blue buttons

below the on-screen 

icon to select that function. Alternately, you can use the side or
up/down arrows      

 

 to scroll to desired

on-screen function and press the "Enter" button

.

Types of Faults

Several possible error conditions on the cable are detected and 

displayed on the screen of your VDV Commander.

cable Fault Description

Miswire

Cable’s wire connection does not follow 

cabling standards.

open

Wire connection is not continuous 

throughout cable length.

short

A pair has a high resistance fault. This 

occurs when the wires are making contact 

with each other due to damage  

or improper termination.  

split

A cable can be wired with correct 

continuity but not with correct pairing. 

This happens most when the cable is 

terminated consistently at both ends but  

in the wrong order.

Length

Displays the pair lengths found. Length 

discrepancies may be determined by these 

results.

Network  

connectivity

Displays network connectivity which 

allows the user to determine if it is 

different than expected.

poE

Displays results in red if voltages are 

lower than expected.

Follow instructions carefully and pay attention to warning 

and caution symbols. Failure to observe warnings can result 

in severe injury, death, and damage to the VDV Commander 

tester.

on/off 

Turn unit On/Off – press the red "On/Off" button 

 to 

activate the VDV Commander or turn it off.

Auto power off

The VDV Commander automatically turns off to conserve 

battery power if no input or activity is performed on the device. 

See “setup” to adjust the length of time before automatic 

power down.

From the main screen, press the blue function button 

 

on the far right below the “setup” symbol 

. Use the  

up and down arrow buttons 

  to scroll through 

the Setup menu and to select an option. 

LcD scREEN

sTART-Up AND sHUT-DoWN

sETUp

Summary of Contents for VDV Commander VDV501-097

Page 1: ...uction Manual VDV Commander TM VDV501 097 ENGLISH Tests Cables MEasures Cable Length with TDR detects Faults Detects and measures PoE Locates and Identifies Cables Tests AcTive Network Save and print reports ...

Page 2: ...l in one product Tests Cables Measures Cable Length with TDR Detects Faults Detects and measures PoE Locates and Identifies Cables Tests Active Network Reporting Link Light Cable Identification up to 20 locations Shield Detection Voltage Warning Low Battery Indicator Multiple Style Tone Generator Color LCD Display Multiple Languages Imperial and Metric Results Auto Power Off Customizable Setup USB...

Page 3: ...loads cable up to 25 5 watts at class 4 Identifies Mode A or B pairs with PoE Active Ethernet Indicates advertised speeds of 10 100 1000base t half or full duplex Can link to network at 10 100base t Tone Generation Tone frequencies 730 Hz and 1440 Hz Test Memory Storage Stores up to 256 cable or network tests with user defined names Safety Compliance CE Disposal Compliance WEEE WARNINGS To ensure ...

Page 4: ...e 1 Test Cable Micro USB to USB A Test Cable Universal RJ12 Jumper 9 Test Cable RJ45 Jumper 9 Coax Adapter Barrel F F Female AA Batteries 6 9 Volt Battery 1 VDV Commander Carrying Case Full color LcD Display UsB port RJ45 Jack coax connector Function Buttons perform the function on the display above each button Arrow Buttons Test Button Enter Button on off Button Back Button Back Button oVERVIEW A...

Page 5: ...tly at both ends but in the wrong order Length Displays the pair lengths found Length discrepancies may be determined by these results Network Connectivity Displays network connectivity which allows the user to determine if it is different than expected PoE Displays results in red if voltages are lower than expected Follow instructions carefully and pay attention to warning and caution symbols Fai...

Page 6: ...omatic timeout from 00 5 99 9 minutes LCD Dimmer Timeout Set the desired automatic timeout from 00 5 99 9 minutes Language Set the desired language from English default to Spanish or French Tone Generator Timeout Set the desired automatic timeout 00 5 99 9 minutes PoE Test Turn the PoE test On or Off Turning the PoE off will allow the VDV Commander to detect a network without running a PoE test Pr...

Page 7: ...to faults using Time Domain Reflectometry TDR Velocity of Propagation VOP is the TDR measurement of the speed of the reflected waveforms compared to the speed of light VOP values can vary among cable types lots and manufacturers In most cases these differences are minor and may be disregarded Cable Testing with Remotes 1 8 Test n MapTM ID Remotes are used to verify connectivity at the opposite end...

Page 8: ...unction button Use the arrow buttons and the Enter button to name the cable test file Press the Save function button to save the cable test file Network Power over Ethernet PoE Testing The VDV Commander PoE test identifies the link capability of a network drop and the connection status VDV Commander detects the presence of PoE PoE class per IEEE 802 3 af at and also measures PoE voltages under loa...

Page 9: ...s a cadence from the VDV Commander through the connected cable The tone is detected by a tone tracing probe Refer to the Accessories section Press the On Off button to power on the VDV Commander Use the left and right arrow buttons to select the tone generator icon and press the Enter button The VDV Commander will automatically activate the tone generator upon entering the tone generator menu Conn...

Page 10: ...eft Click on Save File A Save As dialogue will appear navigate to where you want to save the test results and click Save You can also rename the file in the Save As dialog window The computer software application will remember the last place you saved a file To read previously saved cable tests Click on File Open and select the desired test result file After tests have been saved they will automat...

Page 11: ...atteries Reinsert the batteries and follow the update instructions Note The VDV Commander screen will remain dark until it has been reprogrammed Battery Replacement The VDV Commander is powered by six AA alkaline batteries To replace batteries open the back cover by unscrewing the single screw with a philips head screwdriver Take out the old batteries and replace Slide the new batteries in by foll...

Page 12: ...tools com CUSTOMER SERVICE Warranty www kleintools com warranty Disposal Recycle Do not place equipment and its accessories in the trash Items must be properly disposed of in accordance with local regulations Prior to disposal of this product please contact Klein Tools for proper disposal options ENGLISH ...