2-4
CHAPTER 2 Specifications
Series 5000 V2 Sonar System Operations and Maintenance Manual
P/N 11214512, Rev. 04
2.3.5 A/D Converter
Type:
Pipeline
Resolution:
14 bits
Quantization:
Linear
Sample rate:
Proprietary
2.3.6 Multiplexer
Modulation format:
Pulse code modulation (PCM)
Multiplexing format:
Time division multiplexing (TDM)
Number of channels:
32
Data rate:
29.12 Mbaud
Data format:
NRZ
Bit error rate:
Better than 1x10
-8
(before correction)
2.3.7 Power
Input power:
Powered from the TPU; no additional
power required
2.3.8 Heading Sensor
Accuracy level:
±0.5
RMS
Accuracy tilted:
±1.0
RMS
Resolution:
0.1
Repeatability:
±0.1
2.3.9 Pitch and Roll Sensor
Accuracy:
±0.2
RMS
Resolution:
0.1
Repeatability:
±0.2
2.3.10 Pressure Sensor
Pressure range:
0–750 psig
Accuracy:
±0.10%