background image

OPERATING THE LIFT TABLE

How to use the brake

The brake is located next to the swivel caster on right hand side.
1.  To brake the lift table, press the brake pedal.
2.  To release the brake, lift up the brake pedal.

CAUTION:

 

Put lift table in brake mode when stationary in order to prevent sudden movement.

Lifting the Table

To lift the table, press the lifting pedal several times until the table reaches the desired height. The table 
lowers slightly after reaching the highest position. Maximum Capacity of this table is 330 lbs. (150kg).

WARNING:

 Do not overload lift table, stay within the rated capacity.

Do not load the table on sides or ends only. Load must be distributed on at least 80% of table area.

Lowering the Table

WARNING:

 DO NOT put foot or hand in scissor mechanism. The rotating knob lowers the table.

NOTE:

 The hydraulic cylinder is designed to hold table. As is the nature of the hydraulic system, table 

lowers very slowly over an extended period of time. Please note that the table does not stay at the same 
height indefinitely.

Specifications

Model

Capacity

Table

Table 

Height

Foot Pedal 

Strokes to Elevate

Wheel

Weight

MJ518

150 kg.

330 lbs.

450 x 700 mm

17.7" x 27.5"

220-720 mm

8.6" x 28.3"

28

100 mm

4"

45 kg.

99 lbs.

Service Instructions

Change hydraulic oil every 12 months
Lubricate the following areas every month:

 Fitting of Cylinder/oil, Roller Friction Surface/grease, 

Link Pin/oil, Pedal Fitting Point/oil, Grease Nipple/grease 

Troubleshooting 

If the table does not lift when pressing lifting pedal several times:

•  Adjust the control valve located on  
  the hydraulic cylinder (A) by releasing 
  the set screw and locking nut (B) using a 
  flat screwdriver and a 14mm wrench.
•   Test the control lever and lifting pedal.

A

B

Reviews: