bottom pan. 5 to 20 liters per day of condensation water can be produced while the unit is
running. If more condensation is produced, stop the heat pump and wait for one hour before
checking for water leakage (keep the filter pump running).
Note: a quick way to verify that the water running is because of the condensation. Shut
off the unit and keep the pool pump running. If the water stops running out, it is
condensation. AN EVEN QUICKER WAY IS TO TEST THE DRAIN WATER FOR
CHLORINE. If no chlorine is detected, the drain water is a result of condensation.
Also make sure that the air in and out passages are free, and prevent air out from immediately
re-entering to the air in. (It is important to have min. 2.5m free space at the air out side of the
heat pump).
14. Maintenance and Inspection
The picture below shows a heat pump with lid (top panel) off.
Do not open the Lid (Top panel) when the electrical power is connected to the heat pump.