background image

 

 

 

 

 

 

25.01.2019 

    

Roof Fans

  SMART-EC-6200 

 

 
 

Use and Maintenance Manual 

 

 

 
 
 
 

Roof Fans

 

SMART-EC-6200 

 

 

Summary of Contents for SMART-EC-6200

Page 1: ...1 25 01 2019 Roof Fans SMART EC 6200 Use and Maintenance Manual Roof Fans SMART EC 6200...

Page 2: ...ervations of Producer 4 4 Technical Data 4 5 Structure and Function 5 6 Assembly and Start up 6 7 Operational Use 8 8 Troubleshooting Guide 9 9 Maintenance 9 10 Occupational Health and Safety 9 11 Tra...

Page 3: ...tes relating to the making available on the market of electrical equipment designed for use within certain voltage limits Journal of Laws EC L96 of 29 03 2014 The appliance meets the requirements incl...

Page 4: ...structure in pla ces where the roof fan shall be installed Unsure mounting could cause damage of the de vice risk to personnel people in the vicinity F SMART EC 6200 fan is not appropriate for convey...

Page 5: ...hrough which the air is expelled Under the lower skeleton is located the fan inlet with a flange serving as a mounting element to the roof base Manufacturer suggests installing on sound absorbing roof...

Page 6: ...to install them on roof bases or wall brackets delivery on separate order To reduce the noise level it is advised to apply sound absorbing roof bases After the fan is placed on a roof base it is impor...

Page 7: ...e order Isolating switch ought to be installed by User on one s own in a place convenient for operator The way of connection is illustrated in Fig No 3 First take off the fan hood to get access to the...

Page 8: ...pose see Section 2 of the present Use and Maintenance Manual and when the reservations of manufacturer are not observed see Section 3 of the Use and Mainte nance Manual Consequences of improper use br...

Page 9: ...se the isolating switch IS which should be ordered and installed by User Isolating switch ought to be installed within reach of the servicer Isolating switches IS are offered by KLIMAWENT S A as addit...

Page 10: ...weights placed on the package surface During loading reloading and transport the device should be neither thrown nor knocked down Do not put any additional load on the package It is inadmissible to pu...

Page 11: ...oducts Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign re...

Page 12: ...s SMART EC 6200 25 01 2019 Producer KLIMAWENT S A 81 571 Gdynia ul Chwaszczy ska 194 tel 058 629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 812W83 SMART EC 6200 25...

Reviews: