Roof Fans

  SMART-EC-6200                                      25.01.2019 

 

 

 

2.

 

Application 

 

SMART-EC-6200 roof fans

 are meant for general ventilation of buildings.  They are

 designed for

 

conveying the dry dust of maximum tempe40

C  and 

dustiness not exceeding 0,3 g/m³ 

The devices cannot be applied in atmosphere containing viscous, aggressive contaminants, or 
in atmosphere that create explosion hazard.  
 
 

 

 

3.

 

Reservations of Producer 

 

A. 

Manufacturer is not liable for  any consequences following from the operational use that is  
in contradiction to the purpose of application. 

 

 

B. 

Do 

not install any

 additional elements 

not belonging to the normal device

 structure or acces-

sory set. 

 

 

C. 

Any structural changes  or modifications on the appliance  

on one’s own are not permitted. 

 

 

D. 

Protect the device housing from mechanical damage. 

 

 

E. 

Before the installing, check the load carrying capacity of the wall / building structure in pla- 
ces where the roof fan shall be installed. Unsure mounting could cause damage of the de-
vice,  risk to personnel / people in the vicinity. 

 

 

F.  SMART-EC-6200 fan

  

is not appropriate for conveying the air polluted with a mixture  

of flammable 

substances in a form

 of gas, vapour, mist or dust, that could create the 

explosive atmosphere

.

 

 

 

G. 

Don’t use the fan for conveying the air containing viscous 

compounds that would de-

posit within the appliance,  especially at the impeller. 

 

 

H.  Neither apply the fans  for conveying the air containing aggressive compounds that 

would have destructive effect on the device. 

 

 

I. 

In the course of operational use,

 the maximum impeller rotations 

should not 

exceed their no-

minal rotations. 

 

 

J. 

Manufacturer

 is not responsible 

for any wounds or body lacerations, 

experienced during the

 

improper operational use of the appliance. 

 
 

 

4.

 

Technical Data 

Table No.1 

Type 

Supply 

voltage 

Rotations 

Motor  

rate 

Maximum 

volume flow 

Maximum 

vacuum 

Weight 

 

[V/Hz] 

[1/min] 

[W] 

[m³/h] 

[Pa] 

[kg] 

SMART-EC-6200  3x400/50 

1450 

1000 

6450 

540 

47,6 

Ingress protection  IP44 

 

 

Summary of Contents for SMART-EC-6200

Page 1: ...1 25 01 2019 Roof Fans SMART EC 6200 Use and Maintenance Manual Roof Fans SMART EC 6200...

Page 2: ...ervations of Producer 4 4 Technical Data 4 5 Structure and Function 5 6 Assembly and Start up 6 7 Operational Use 8 8 Troubleshooting Guide 9 9 Maintenance 9 10 Occupational Health and Safety 9 11 Tra...

Page 3: ...tes relating to the making available on the market of electrical equipment designed for use within certain voltage limits Journal of Laws EC L96 of 29 03 2014 The appliance meets the requirements incl...

Page 4: ...structure in pla ces where the roof fan shall be installed Unsure mounting could cause damage of the de vice risk to personnel people in the vicinity F SMART EC 6200 fan is not appropriate for convey...

Page 5: ...hrough which the air is expelled Under the lower skeleton is located the fan inlet with a flange serving as a mounting element to the roof base Manufacturer suggests installing on sound absorbing roof...

Page 6: ...to install them on roof bases or wall brackets delivery on separate order To reduce the noise level it is advised to apply sound absorbing roof bases After the fan is placed on a roof base it is impor...

Page 7: ...e order Isolating switch ought to be installed by User on one s own in a place convenient for operator The way of connection is illustrated in Fig No 3 First take off the fan hood to get access to the...

Page 8: ...pose see Section 2 of the present Use and Maintenance Manual and when the reservations of manufacturer are not observed see Section 3 of the Use and Mainte nance Manual Consequences of improper use br...

Page 9: ...se the isolating switch IS which should be ordered and installed by User Isolating switch ought to be installed within reach of the servicer Isolating switches IS are offered by KLIMAWENT S A as addit...

Page 10: ...weights placed on the package surface During loading reloading and transport the device should be neither thrown nor knocked down Do not put any additional load on the package It is inadmissible to pu...

Page 11: ...oducts Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign re...

Page 12: ...s SMART EC 6200 25 01 2019 Producer KLIMAWENT S A 81 571 Gdynia ul Chwaszczy ska 194 tel 058 629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 812W83 SMART EC 6200 25...

Reviews: