background image

 

 

 

 

 

 

04.06.2019 

    

roof radial fans 

  

WPA

-

D

-

N

 

 

 

 

1.

 

Introductory Remarks 

The purpose of the present User’s Manual  is to supply User

  

with directions within the range of 

application, installation

start-up and the operational 

use of the

 

WPA-D-N roof radial fans

 

Installing, start up and operational use  are exclusively admissible after getting acquain-
ted with the contents of the Use and Maintenance Manual

With regard  to continuity of work  carried on improvement  of our products,  we reserve for our-
selves the revision possibility  of the draft

  

and technological changes improving their functional 

features and safety. 

 

The construction of the 

WPA-D-N roof radial fans

 meets the requirements of the current state  

of technology as well as the safety and health assurances included in: 

 

  2006/42/EC

 

Machinery Directive 

of the European Parliament and of the 

Council

 of 

May

 

17

th

2006  on machinery 

– amending the 95/16/EC (recast)

 /

Journal of Laws EC L157 of 09.06.2006, page 24

/

 

 

 

  2014/35/EC Directive  

of the European Parliament and of the Council of 

February 26

th

2014

   

on the harmonisation 

of the laws of the Member States

 

relating to 

the making available on the 

market of electrical equipment designed for use within certain voltage limits. 

/

Journal of Laws EC L96  of 29.03.2014

/

 

 
 

The appliance meets the requirements included in:

 

 

  2009/125/EC (ErP)

 

Directive 

of the European Parliament and of the Council of October 21

th

2009 establishing a framework

  

for the setting  of ecodesign requirements for energy-related 

products  /

Journal of Laws L285 of 31.10.2009

 

 

  327/2011

 (

EU

Commission

 

Regulation 

of March 30

th

, 2011 on 

implementing the

 

2009/125 

/EC Directive

 of the European 

Parliament

 and of 

the Council

 with regard to ecodesign requi-

rements for fans driven by motors with an electric input power between  
125W and 500 kW   /

Journal of Laws L90  of 06.04.2011

/

 

 
 

The device has been constructed

 and produced

  

on the basis of following harmonized standards: 

 

 

EN ISO-12100:2012 

 
 

 

“Safety of machinery – 

Basic concepts, general

 princi-  

 

 

 

ples 

for design.  Risk assessment and risk reduction”. 

 

 

 

 

 

EN 60204-1:2018-12

 

 
 

 

“Safety of machinery – Electrical equipment of machi- 

 

 

 

nes

.  Part 1:  General requirements”. 

 

 

 

 

 

EN 60034-1:2011 

 
 

 

“Rotating

  

electrical

  

machines  

  

Part 1:  Rating data  

 

 

 

and parameters”. 

 

 

 

 

 

EN ISO 5802:2008/A1:2015-07 

 
 

 

“Industrial Fans – Performance testing

 in situ of instal

 

 

 

ling” 

 

 

 

 

 

EN ISO 13857:2010 

 
 

 

“Safety of machinery  –

  

Safe distances to prevent ha-  

 

 

 

zard zones being

  

reached by upper and lower limbs”. 

 

2.

 

Application 

WPA-D-N roof fans have been designed  for general ventilation and for local ventilation applica-
tions.  They are installed outside the rooms 

(outdoor 

application

)

 on roof bases or wall brackets. 

As they feature

 increased fan pressure, they are

 

efficient in application in installations with local 

exhausts. 

They fans are designed for

 conveying

 the air of

 dustiness not 

exceeding 0,3 g/m

3

without

 viscous 

impurities, aggressive contamination or compounds creating hazard of explosion. 
 

 

Summary of Contents for WPA-10-D-3-N

Page 1: ...1 04 06 2019 roof radial fans WPA D N Use and Maintenance Manual Roof radial fans WPA D N...

Page 2: ...ions of Producer 4 4 Technical Data 4 5 Structure and Function 8 6 Assembly and Start up 9 7 Operational Use 10 8 Troubleshooting Guide 10 9 Maintenance and Control 10 10 Occupational Health and Safet...

Page 3: ...and of the Council of October 21th 2009 establishing a framework for the setting of ecodesign requirements for energy related products Journal of Laws L285 of 31 10 2009 327 2011 EU Commission Regulat...

Page 4: ...ssive pollutants which will destructively effect the device structure I During operation the maximum impeller rotations should not exceed the nominal rotations J Manufacturer is not responsible for wo...

Page 5: ...25 60 160 160 194 6 7 0 495 140 WPA 5 D 3 N WPA 6 D 1 N 915 550 60 160 160 194 6 7 0 495 140 WPA 6 D 3 N WPA 7 D 1 N 965 570 60 200 160 194 6 7 0 535 155 WPA 7 D 3 N WPA 8 D 3 N 990 600 60 200 200 224...

Page 6: ...160 194 6 7 0 815 140 500 WPA 5 D 3 N WPA 6 D 1 N 715 550 60 160 160 194 6 7 0 815 140 500 WPA 6 D 3 N WPA 7 D 1 N 815 570 60 200 160 194 6 7 0 840 155 500 WPA 7 D 3 N WPA 8 D 3 N 840 600 60 200 200...

Page 7: ...th vertical outlet Type of the fan Elbow Type of the elbow Weight kg WPA 5 D N KL 160 WPA 1 8 WPA 6 D N KL 160 WPA 1 8 WPA 7 D N KL 200 WPA 2 4 WPA 8 D N KL 200 WPA 2 4 WPA 9 D N KL 200 WPA 2 4 WPA 10...

Page 8: ...2870 2880 2880 2880 2900 2930 11 Specific ratio 1 007 12 Fan disassembly recycling and disposal at the end of operational life see the sections concerning the maintenance and recycling 13 To minimali...

Page 9: ...n case of inconsistency the connection cannot be executed Connection to the electrical power system has to be executed by User on one s own by selec ecting the right type and section of the supply cab...

Page 10: ...and the motor to technical revision the electrical motor ought to be examined according to the instructions of the motor manufacturer Every several years examine the mechanical and electrical connect...

Page 11: ...ct the the device from atmospheric factors weather conditions and from damage indents The device ought to be stored in dry and well ventilated rooms 12 Terms of warranty The period of warranty for the...

Page 12: ...ournal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign requiremen...

Page 13: ...13 04 06 2019 roof radial fans WPA D N NOTES...

Page 14: ...14 roof radial fans WPA D N 04 06 2019 NOTES...

Page 15: ...15 04 06 2019 roof radial fans WPA D N NOTES...

Page 16: ...ent com pl 807W11 WPA 5 D 1 N 04 06 2019 EN 807W12 WPA 5 D 3 N 04 06 2019 EN 807W13 WPA 6 D 1 N 04 06 2019 EN 807W14 WPA 6 D 3 N 04 06 2019 EN 807W15 WPA 7 D 3 N 04 06 2019 EN 807W16 WPA 7 D 3 N 04 06...

Reviews: