Klindex
S.r.l.
Data ultimo aggiornamento: 6 / 08 / 2004
Pag. 12 di 33
INSTRUCTIONS
GB
IDENTIFICATION PLATE
This machine holds an Identification Plate and a serial number. Make sure the machine has been provided by an Identification Plate, otherwise inform
the manufacturer and/or the dealer immediately. Machines without plates must not be used and the manufacturer declines all responsibility for them.
Any product without an Identification Plate must be considered anonymous and potentially dangerous.
BEFORE STARTING UP
MACHINE SETUP INSTRUCTIONS
Follow these instructions before connecting the machine to the power supply:
•
Move every switch to location indicated by 0
•
Close the valve “SCARICO ACQUA CALDAIA”
•
Close the valve “SCARICO SERBATOIO ACQUA LAVAGGIO”
•
Close the valve “SCARICO SERBATOIO ACQUA CALDAIA”
•
Close additional valve di “SCARICO VAPORE CALDAIA”
•
Connect vacuum cleaner to the power socket located on the control board.
•
Place switch located on top of the vacuum cleaner on 1.
HOW TO CONNECT TO POWER SOCKET
Make sure you have the right frequency and voltage before putting the plug in the power sockets. Check instructions showed on the machine
Identification Plate.
This machine ha san approved three wires electric cable. Yellow wire (or yellow/green) is the grounding. This machine must be connected to a regular
power socket with grounding.
WARNING: Power socket must have grounding.
ATTENZIONE: Any responsibility of the manufacturer must be cancelled in case of a lack of observance of these instructions. Any user of this
machine must make sure all provisions of the law and/or permits regarding the use will be observed. Operator must also check safety conditions like: a)
sufficient power system b) absence of explosives, inflammable or corrosive powders.
WARNING: Do not cut the plug. Do not use adaptors. Only a qualified electrician can replace the plug if needed. Only a qualified operator can replace
burned, cut or damaged electric cable.
WARNING:
Only a qualified staff can replace a burned, cut or damaged electric cable or plug.
CONTROL PANEL
Machine control panel has been provided by the following elements:
•
Steam ready pilot light (Spia pronto vapore)
•
Resistance switch n°1 (Resistenza 1)
•
Resistance switch n°2 (Resistenza 2)
•
Boiling water switch (Pompa Acqua Bollente)
•
Steam switch (Vapore)
•
Vacuum system switch (Accesnsione Aspiratore)
•
Hot water pump (Pompa Acqua Calda)
•
Disinfectant pump (Pompa disinfettante)
TANKS FILLING INSTRUCTIONS
This machine has been provided by three tanks, as pictured, containing:
•
Water for boiler
•
Disinfectant or deodorant liquids
•
Water for cleaning
•
NOTE:AN ACOUSTIC SIGNAL
INDICATES THE EMPTY BOILER
WATER
Scarico vapore caldaia
Summary of Contents for Vapor 8 PROFESSIONAL
Page 15: ...Klindex S r l Data ultimo aggiornamento 6 08 2004 Pag 15 di 33 ESPLOSO MACCHINA ...
Page 16: ...Klindex S r l Data ultimo aggiornamento 6 08 2004 Pag 16 di 33 ACCESSORI IN DOTAZIONE I ...
Page 18: ...Klindex S r l Data ultimo aggiornamento 6 08 2004 Pag 18 di 33 ACCESSOIRES DOTATION F ...
Page 23: ...Klindex S r l Data ultimo aggiornamento 6 08 2004 Pag 23 di 33 ACCESSORI OPTIONAL ...
Page 29: ...Klindex S r l Data ultimo aggiornamento 6 08 2004 Pag 29 di 33 VALVOLA DI SICUREZZA ...