KCS-ID Manual
Klippel R&D System
Note:
Bl(0) can only be imported if no laser is used (switch off
Laser Connected
in the
Peripherals
category). If a laser is used (which is highly recommended), Bl(0) is identified accurately on the KCS
Server.
1.4.2
Additional Options
Stimulus
The
Stimulus
settings are set to
Automatic
by default. You can select a higher
Start Voltage
if you
use a big speaker and want to accelerate the ENLARGEMENT MODE. In some cases, the
Level
might
be set to
Manual
to fine-tune
X
max
(see 1.6.2).
Peripherals
Select whether laser/microphone sensors are used in this measurement. It is recommended to use
both, however sometimes the laser might not have access to the transducer’s membrane and
cannot be used. Note that a microphone calibration is not required for this measurement.
Advanced
Save Intermediate Results
saves the results of each measurement block into a new KCS Monitor
operation. It is not recommended to activate this option. However, KLIPPEL support might require
this data in case of problems.
1.4.3
Limit Parameters
In the ENLARGEMENT MODE, the excitation voltage is incrementally increased until the first limit
parameter is reached or exceeded. Following limit parameters are available:
1.
X target
-
Maximum absolute peak voice coil excursion that shall be used in the target
application. If a laser is used, the peak displacement value is measured by a laser sensor. If
no laser is used, it is calculated by a linear speaker model and a Bl(X=0) import which e.g. can
Property page of KCS-ID module