Room Temperature
Press key 2 to select
“SET ROOM TEMP”
mode to modify room temperature. Press keys 1 and 2. The
display appears as in figure below during this operation
Set
!
1
2
3
4
5
6
Press key 4 or wait a few seconds to confirm the wanted value setting.
ATTENTION: The room thermostat temperature is taken into account if the remote control to be applied to
the wall is connected
(also see
”Menu 04” )
.
Room probe must be enabled in the remote control also
(see
“Remote control” manual)
.
-
DHW Temperature
Press key 5 to select
“SET DHW”
mode to modify DHW temperature. Press keys 5 and 6. The display must
appear as in figure below during this operation.
Set
!
1
2
3
4
5
6
Press key 4 or wait a few seconds to confirm the wanted value setting.
Alarm signals
The board intervenes and signals the occurred irregularity in case of functioning anomaly, operating in
different mode depending on type of alarm. The following alarms are foreseen in the board.
DISPLAY
ORIGIN OF ALARM
WATER PROBE ACTIVE ALARM
Faulty or disconnected water temperature probe.
FLUE GAS PROBE ACTIVE ALARM
Faulty or disconnected flue gas temperature probe.
HOT TEMP ACTIVE ALARM
Flue gas over-temperature. When flue gas temperature is more than 260°C. The
display shows the wording
“HOT FLUE GAS”
before displaying the alarm, or
when flue gas maximum temperature is reached (Pr14).
NO IGNIT- ACTIVE ALARM
No ignition. When flue gas minimum temperature (Pr13) is not reached within
maximum ignition cycle time (Pr01).
NO PELLET ACTIVE ALARM
Sudden switch-off during work phase. When, during work, the flue gas
temperature drops below minimum threshold (Pr13).
Every alarm causes the equipment to immediately switch-off.
After time set on Pr11 (alarms delay) alarm state is reached; press key 4 to reset it.