Orientation and initial vertical rise: The flue system should run as vertically as possible as any deviations off the
vertical can adversely affect the draw. 45º is the maximum off-vertical angle than may be used. Non-vertical sections
should make up no more than ¼ of the effective height of the flue or chimney (measured from the appliance outlet to
the top of the chimney), and must not be longer than 2,000 mm.
There should be no more than 4 bends in the system, with a tee counting as 2 bends.
Securely fix and support the system to avoid vibration and movement.
90º bends should not be used. When using the rear outlet on the appliance a 90º tee should be used with sweeping
access and debris collection space.
When using the rear outlet any horizontal run should not exceed 150mm, including the arm of the tee.
An initial vertical run of 600mm from the appliance is recommended before any change in direction.
Cleaning Access: The system must provide access so that the entire system can be swept and cleaned.
Flue pipes must not pass through rooms in which the installation of combustion devices is prohibited.
IT IS STRICTLY FORBIDDEN TO INSTALL FLUE DAMPERS/BUTTERFLY VALVES.
Heat shielding: If combustible materials are present then minimum separation distances will need to be adhered or
heat shielding will be required. Please refer to Building Regulations Approved Document J, and also these installation
instructions.