39
Klübermatic PRO C
7.
Trouble Shooting
7.1
Error Messages on the Display
Possible errors of the lubrication system and the application are detected by the electronic control system and
are indicated on the display. If an error is displayed, the system is switched OFF until the cause of the error has
been eliminated and the error message has been acknowledged.
Error messages are acknowledged and reset by pushing the SELECT button. However, error messages
“ ” and “ ” are automatically acknowledged when errors are corrected (see remedial measures).
7.2
Fault Signaling via the Connected Control System
,QFDVHRIDPDOIXQFWLRQWKHFRQQHFWHGFRQWUROV\VWHPRI\RXUHTXLSPHQWPHUHO\LQGLFDWHVDQXQVSHFL¿HG
malfunction since the control system only receives a “Low” signal from the lubricator. This means that if your
control system indicates a malfunction, you have to use the display of the lubricator to determine the cause of
the malfunction (refer to chapter 7.1).
7.3
Trouble Shooting Guide
If there are malfunctions during the operation of the lubrication system, please check for possible causes using
the following chart (refer to chart 8).
Every time that an error message is displayed, the red LED is also blinking.
Indication
of the
display
Error
Possible cause
Remedial measures
E I
/XEULFDWRUKDVEHHQVZLWFKHGRႇ
Excess motor current of the
lubricator motor due to a blocked
outlet
Clear the blockage and
acknowledge the fault by
pushing and holding down the
SELECT button
E4
/XEULFDWRUKDVEHHQVZLWFKHGRႇ
Drive mechanism is defective
Exchange the drive unit
LC
System does not detect the PRO LC No PRO LC installed
Install an PRO LC
L
green LED
blinking
Low voltage of back-up battery
(lubrication system functions
correctly)
Battery PRO B (back-up battery)
empty
Insert a new battery PRO B
(back-up battery) and use a
full PRO LC
No display
System gets no power from the
back-up battery
No battery PRO B (back-up battery)
inserted
Insert battery PRO B
(back-up battery)
In addition to the above, the following malfunctions can occur when a Klübermatic distributor PRO MP-6
is connected to the lubrication system:
E0
Lubrication system has been
VZLWFKHGRႇ
Excess motor current of the
Klübermatic MP-6
Replace Klübermatic
distributor PRO MP-6
F I
to
f6
Error at the displayed
lubrication point
Excess motor current of the
lubricator motor caused by a
blocking of the displayed outlet
Clear the blockage and ack-
nowledge the fault by pushing
and holding down
the SELECT button
E2
Lubrication system has been
VZLWFKHGRႇ
Outlets of distributor not correctly
recognized
Replace distributor
E3
Lubrication system has been
VZLWFKHGRႇ
Timeout while activating distributor
Connection cable damaged
Replace distributor
Replace connection cable
E5
2XWOHWFRQ¿JXUDWLRQPLVVLQJ
Outlets were not activated
Activate desired outlets
7XUQRႇSRZHUVXSSO\RQ
PRO C before you
acknowledge error
messages)
chart 8
Summary of Contents for Klubermatic Distributor PRO MP-6
Page 1: ......
Page 7: ...1 Klübermatic PRO 1 ...
Page 27: ...21 Klübermatic PRO C 21 ...
Page 47: ...Klübermatic PRO PRO C LINE 41 41 ...
Page 50: ...Klübermatic PRO PRO C LINE 44 ...
Page 51: ...Klübermatic Distributor PRO MP 6 45 45 ...
Page 73: ...67 Drilling template Drilling template Klübermatic Distributor PRO MP 6 45 ...