HPO-9007 Series Gateways Installation Guide 

6 923-019-05B

IMPORTANT NOTICES

NOTE: 

Contains FCC ID SZV-STM300U. 

902 MHz devices comply with Part 15 

of the FCC Rules. Operation is subject 

to the following two conditions: (i.) 

these devices may not cause harmful 

interference and (ii.) these devices 

must accept any interference received, 

including interference that may cause 

undesired operation.

The material in this document is for information 

purposes only. The contents and the product it 

describes are subject to change without notice.
KMC Controls, Inc. makes no representations or 

warranties with respect to this document. In no 

event shall KMC Controls, Inc. be liable for any 

damages, direct, or incidental, arising out of or 

related to the use of this document.
The KMC logo is a registered trademark of KMC 

Controls, Inc. All rights reserved.
TEL: 574.831.5250 

FAX: 574.831.5252 

e-mail:  

info@kmccontrols.com

© 2020 KMC Controls, Inc. 

Specifications and design subject to change without notice 

The sensors may also need to be 

discovered again to see the icon and 

EEP in the Gateway Sensor List section 

of the EnOcean Sensor Port object. See 

Add Sensors on page 3

. (Restarting 

the controller through software may 

also cause a temporary loss of values 

but should not require a new discovery 

of the sensors.)

MAINTENANCE

To clean the case or display, use a soft, damp 

cloth (and mild soap if necessary).

Summary of Contents for Conquest HPO-9007 Series

Page 1: ... into the backplate until the screw clears the cover NOTE The hex screw should remain in the backplate INTRODUCTION Complete the following steps to Mount a KMC Conquest HPO 9007NW or HPO 9007DW gateway Connect it to a KMC Conquest BAC 59xx 9xxx controller Discover wireless sensors NOTE The HPO 9007s only receive signals from sensors They do not transmit signals to devices NOTE See the data sheet a...

Page 2: ...nnect software ver 1 0 13 x or later KMC TotalControl software ver 4 5 0 x or later See the documents or Help systems for the respective KMC tools for more information If the the HPO 9007 is connected to an optional HPO 9001 NetSensor distribution module for use Hex Screw 2 Pull the cover off the backplate CONNECT ETHERNET CABLE 3 Feed the Ethernet patch cable from the Conquest controller through ...

Page 3: ...that is inside of the sensor body Add Sensors Method 1 Automated KMC Sensor Discovery NOTE For devices other than KMC STW THW sensors use Method 2 1 On the back of the sensor press the Learn button on the side or top of the button body dependent on the model with a small screwdriver 2 In Gateway Sensor List Properties wait until the fields for the sensor to populate with an icon and profile NOTE I...

Page 4: ...bject column and select the relevant AV object s in the drop down box es 5 If desired click in the Location column to add a description of the sensor s location 6 Click Save Changes Configure Value and Programming Objects 1 Configure the relevant AVs as needed from the above steps e g add object names and units and click Save Changes NOTE For temperature in degrees C or humidity only you are done ...

Page 5: ...ill be transmitted within a few minutes NOTE Momentarily pressing the Learn button sends a new identification transmission immediately but that transmission does not include sensor temperature setpoint or humidity values USE OF HPO 9001 DISTRIBUTION MODULE To use multiple HPO 9007 gateways and or STE 9000 series NetSensors on a single controller an HPO 9001 distribution module is required The HPO ...

Page 6: ...ith respect to this document In no event shall KMC Controls Inc be liable for any damages direct or incidental arising out of or related to the use of this document The KMC logo is a registered trademark of KMC Controls Inc All rights reserved TEL 574 831 5250 FAX 574 831 5252 e mail info kmccontrols com 2020 KMC Controls Inc Specifications and design subject to change without notice The sensors m...