This cable can be used connecting the DAP 26 to the CAN port interface box, using
your multicore system (i.e. XLR). Use such cable also for linking the CAN bus from
unit to unit. Do not forget connecting the CAN terminator plug to the free connection
port of the last unit, otherwise the CAN transmission could be disturbed.
1
2
3
1
5
3 2
4
7
8
9
6
1
5
3
2
4
7 8 9
6
1
2
3
Digital Audio Input
Digital Audio Output
DIGITAL
INPUT
OUTPUT
The digital input accepts digital audio signals according to AES/EBU with a bit rate of
16 to 24 and a sampling frequency of 32 to 96 kHz using an internal format-/sample
rate converter chip. The digital audio output loops the selected input (analog/digital)
as a 24-bit/96 kHz AES/EBU signal for cascading additional units or recording the
signal to a studio digital recorder. All digital connections are transformer- balanced for
maximum protection against ground loops.
1
2
3
1
2
3
Digital Audio Connection Cable (AES/ EBU) w. 110 Ohms
We do not recommend using “normal microphone cable” for AES/EBU connections
also when it ‘seems’ to work. Only specified 110 Ohms digital audio cable will give a
proper connection without data loss and digital drop-outs.