Functional units
The DAP 26 offers a lot of functional units for general audio processing using a
powerful DSP mainframe such as 9 filter banks with each 5 configurable filters of 9
different types, 6 crossover units with two combinable filters out of 3 types, 3 master
delays (up to 2000 ms / 685 meters), 6 channel delays (up to 500 ms / 170 meters)
and 6 dynamic processors (compressor / limiter / noise gate).
All this functional units can be programmed either directly on the hardware unit or by
using the real-time control software
‚KMEControl’
..
Switches and Knobs
Front side
IN A
IN B
LIMIT
L IMIT
LIMIT
0
+
dB
-60
CLIP
0
+
dB
-60
0
+
dB
-60
0
+
dB
-60
MU TE
dB
-6
+6
MU TE
dB
-6
+6
MU TE
d B
-6
+6
MU TE
MU TE
MU TE
d B
-6
+6
dB
-6
+6
dB
- 6
+6
K.M.E. DAP26 V0.1
Preset Configuration
Choose an option!
Input level meters
Two 10-digit digital level meters help to set the correct input level on the analog audio
inputs or to monitor the digital audio input level.
The graphic below shows different peak input levels on your unit:
a
b
c
d
a) too less input level
b) input level OK
c) maximum input level
d) too much input level – clipping may occur
The analog input circuit contains a limiter unit for preventing the A/D- converters from
clipping. Nevertheless the analog input level must not exceed the red LED of the
input level meter to prevent reproduction of a distorted signal. Set the source level
that only the yellow LEDs light up in peaks.