There might be one (or more) of the following problems:
• the DAP 26 is switched off
Solution:
switch ’on’ the DAP you want to communicate with
• the DAP 26 is not connected to the selected COM port
Solution:
check the connection between the DAP 26 and your computer. Did
you use the correct COM port? Is there any software to be installed using a
USBtoRS232 converter on systems without ‘native’ COM ports (refer to the
manual of the specific converter).
• COM port is used by another application
Solution:
Some programs, especially serial MIDI device drivers block COM
ports. If possible deactivate all programs you do not need at the time you want
to use your computer programming a DAP 26. Try using another COM port or
use a USBtoRS232 converter connected to the USB port of your computer.
• You are using the wrong cable
Solution:
Do only use cables according to the K.M.E. specification to avoid
communication errors or even damages of both the DAP 26 or your computer.
• You are using the wrong communication port on the DAP 26
Solution:
Only use the upper connector labelled ‚RS232/CAN’ for serial
communication with a PC COM port. Make sure that nothing is connected to the
lower port in RS232 mode!
• The DAP 26 is not in RS 232 mode (LED does not light)
Solution:
Operate the switch beside the connectors to activate RS 232 mode.
The yellow LED must light up if you want to use RS 232 communication.
• There is another problem...
Solution:
Contact the K.M.E. support.