III. A Variety of Protection Functions
3.1
Frost Protection Function:
In cooling, dehumidification, or economic power saving mode, if the
temperature of the exhaust pipe is too low, the machine will automatically enter
protection status; if the temperature of the exhaust pipe rises to a certain
temperature, it can automatically revert to normal operation.
3.2
Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will
automatically sound an alarm, and the LDC temperature display area will show
"FL". At this point, you need to move the drainage pipe connecting the machine
or the water outlet to sewer or other drainage area to empty the water (details
see
Drainage Instruction
s at the end of this chapter). After the water is emptied,
the machine will automatically return to the original state.
3.3
Automatic Defrosting (heating and cooling models have this function):
The machine has automatic defrosting function: during defrosting, heating symbol
on the display screen will flash.
3.4. Automatic Thermal Protection:
To protect the service life of the machine, the machine has automatic thermal
protection in heating mode. During the protection period, the compressor and the
lower motor will stop operation and will automatically return to normal heating state
after the temperature of the machine recovers.
3.5 Protection Function of the Compressor
:
To increase the service life of the compressor, it has a 3-minute delay booting
protection function after the compressor is turned off.