Temperature 

class

M1 (-1°C bis +5°C)

M2 (-1°C bis +7°C)

Climate class

III (25°C; 60% rF)

Supply voltage

230V; 50Hz

Power con

-

sumption

246W

Power con

-

sumption at 

temperature 

class M1/24h

KIM1GXT100H100AL108 

1,92 kWh

KIM2GXT100H100AL108

1,81 kWh

KIM1GXT00H100AL140 

2,1kWh

KIM2GXT100H100AL140 

1,6 kWh

KIM1GXT100H100AL200 

2,55 kWh

Protection art

IP44

Protection class

1

Refrigerant 

R290

Capacity 

0,15kg

 

17

Troubleshooting and Service

Electric shock and risk of ignition!

If work is carried out improperly on the 

electrical system or on the refrigeration 

system improperly: there is considerable 

potential for danger.

• 

Only have work on the electrical system 

and the refrigeration system carried out 

by authorized KMW customer service. 

• 

Never allow untrained or unauthorized 

persons to work on the electrical system 

or the refrigeration system.

In the case of a fault, check the following 

points:
• 

Is the power cord plugged in properly?

• 

Is there voltage at the socket?

• 

Is the display active on devices with an 

electronic temperature controller?

If the temperature in the refrigerator com

-

partment is too high, check the following 

points:
• 

are the goods stored were too warm 

stored in accidentally?

• 

Did you have a longer power outage 

previously?

Contact KMW customer service if the fault 

is not due to any of the causes listed here. 

When contacting KMW Customer Service, 

always give the serial number of the

refrigerated island and the type of fault or 

a description of the malfunction. Contact 

KMW customer service if loud noises and/

or strong vibrations occur on the device in 

any case.

Contact for service queries (e.g. with re

-

gard to maintenance and service, repairs, 

etc.) in principle to your regionally respon

-

sible KMW customer service.

If you do not know the customer service 

responsible for your region, you can con

-

tact the central KMW customer service 

alternatively at the following address:

Contact address:

KMW Kühlmöbelwerk Limburg GmbH

Limburger Strasse 80

D- 65555 Limburg

Telefon 06431 599 0

Service 0800 59 95 95 9

E-Mail: kmw@kmw-limburg.com

Service: service@kmw-limburg.com

Internet: 

www.kmw-limburg.com

Technical data

Year of Manu

-

factoring

since 2022

Summary of Contents for KIM 108 Series

Page 1: ...Operating Manual Refrigerated display cabinet Borkum Commercial refrigerated cabinet ...

Page 2: ...2 defrost running cooling is running fans are running ...

Page 3: ...ine impact protection light switch LED optional air intake grille thermostat controller button forward back program keys display icons temperature display substructure adjustable feet with thread M10 sliding glass lid temperature display weighted air inlet and air outlet temperature 3 ...

Page 4: ...nnect the refrigerated island from the power supply 12 Cleaning 13 Do not clean with 13 Defrosting 13 Defrosting of devices without bus connection 13 Defrosting of devices with bus connection 13 Maintenance 14 Risk of injury 14 Risk of short circuit 14 Decommissioning transport and storage 15 Productdetails and funcionality 15 Climate class 15 Cooling unit 15 Housing and cooling storage 15 Tempera...

Page 5: ...specific guidelines and laws abroad Keep these operating instructions for further use If you pass the refrigerated island on to third parties be sure to inclu de these operating instructions 5 Explanation of symbols The following symbols and signal words are used in this manual on the refrigera ted island or on the packaging This signal symbol word indicates a ha zard with a high level of risk whi...

Page 6: ...es Warning of explosive substances Entering the area pro hibited Read the manual Intended use The refrigerated island is a commercial refrigeration furniture It is designed as sales furniture for packaged food in the temperature class M1 and MS in the self service area This refrigerated island is not suitable for use on board ships or aircraft It must be ensured at all times that the set and reach...

Page 7: ...ype plate of the refrige rated island as well as on the product data sheet which you can obtain from KMW customer service Only use the cooling island as described in this user manual Any other use is con sidered improper and can lead to pro perty damage or even personal injury The refrigerated island is not a child s toy The manufacturer assumes no liability for any injury loss or damage resulting...

Page 8: ...en cy of the socket correspond to the information on the type plate Only connect the refrigerated island to an easily accessible socket so that you can quickly disconnect the refri gerated island from the mains in the event of a fault Do not operate the cooling island if it is visibly damaged or if the mains con nection cable or mains plug is defect If the mains connection cable of the refrigerate...

Page 9: ...or repairs This refrigerated island contains elec trical and mechanical parts that are essential to protect against sources of danger Do not operate the refrigerated island with an external timer or a separate telecontrol system Incorrect installation of the tempera ture controller installed in the refrige rated island can lead to an electric shock The temperature controller is installed and adjus...

Page 10: ...akes to re pair minor damage to the refrigerated island that does not impair any technical functions e g dents in the housing cau sed by shopping trolleys If there is damage to the refrigeration system or the electrics the KMW custo mer service must be informed immedia tely Otherwise there is a considerable risk of injury In the event of improper handling or use there is a risk of damaging the ref...

Page 11: ...ld not be exposed to excessive drafts or large heat sources This can affect the per formance of the refrigerated island In the case of block or row configura tions these must be ordered in ad vance to match Other installations and superstructures should be avoided at the installation site in order to prevent heat build up Before using it for the first time clean all parts of the refrigerated islan...

Page 12: ... Make sure that no other consumers are connected to the sockets for connecting the refrige rated island KMW recommends using a cable duct on the floor with sockets built into it or mounted on it to connect the refrigerated island Electric circuit protection Before you connect the refrigerated island to a circuit you must ensure that the corresponding circuit is correctly protected Miniature circui...

Page 13: ...iple of so called hot gas defrosting It is therefore usually not necessary to defrost the refrigerated island manually The start time of the automatic defrosting process is preset at the factory In exceptional cases it may be necessary to defrost the refrigera ted island manually e g due to a fault improper installation overloading after cleaning or due to other sources of inter ference The way yo...

Page 14: ...crape off any existing lay er of ice or frost with pointed objects or tools This could damage the evapora tor Risk of injury In the event of improper handling or use there is a risk of injury from rotating fans and sharp edges When cleaning below the floor display the mains plug must be pulled out befo re cleaning Always use suitable protective gloves when cleaning the cooling island to avo id inj...

Page 15: ...ling devices must always correspond to one of the climate classes 0 to 8 ac cording to the ISO 23953 2 standard The climate class specifies specifications for the environment in which the device is operated The cooling island is designed as a device of climate class 3 for which a maximum ambient temperature of 25 C and a maximum relative humidity of 60 are specified If the actual tem perature and ...

Page 16: ...island manually usually To do this observe the procedure in the Clea ning and maintenance chapter Temperature controller Refrigeration controller With the help of the temperature cont roller the temperature in the goods area is regulated to an adjustable setpoint The temperature controller is set electro nically All necessary settings for tempe rature control and automatic defrosting are preset at...

Page 17: ...e on devices with an electronic temperature controller If the temperature in the refrigerator com partment is too high check the following points are the goods stored were too warm stored in accidentally Did you have a longer power outage previously Contact KMW customer service if the fault is not due to any of the causes listed here When contacting KMW Customer Service always give the serial numb...

Page 18: ... External dimensions 1980x980x1005mm Internal dimensions 1875x700x412mm Display area 1 31 m Weight 260 kg Disposal Dispose of packaging Discard the packaging unmixed Give cardboard to the waste paper foils to the recyclables collection Dispose the cooling islang Applicable in the European Union and other European countries with systems for separate collection of recyclables Old devices must not be...

Page 19: ...nized standards for Machinery Directive 2006 42 EG DIN EN 60335 1 2020 08 VDE 0700 1 2020 08 DIN EN 60335 289 2018 10 VDE 0700 89 2018 10 DIN EN 62233 2008 11 VDE 0700 366 2008 11 DIN EN 62233 Correction 1 2009 04 VDE 0700 366 correction 1 2009 04 DIN EN ISO 12100 2011 03 Applied harmonized standards for EMC directive 2014 30 EU DIN EN IEC 61000 3 2 2019 12 VDE 0838 2 2019 12 DIN EN 61000 3 3 2020...

Page 20: ...W Kühlmöbelwerk Limburg GmbH is inadmissible and punishable This applies in particular to reproductions translations microfilms and the feeding and processing in electronic systems Manufactured in 2022 by KMW Kühlmöbelwerk Limburg GmbH Limburger Straße 80 D 65555 Limburg Imprint KMW Kühlmöbelwerk Limburg GmbH Gewerbegebiet Offheim Limburger Straße 80 D 65555 Limburg Tel 49 0 64 31 5 99 0 Fax 49 0 ...

Reviews: