Diaphragm Vacuum Pumps N 920__.18 and N 920 KT.29.18G
Servicing
Translation of original Operating Instructions, English, KNF 121416-121419 07/18
17
8.3. Changing Diaphragm and Valve Plates
8.3.1. N 920 AP.18 and N 920 AP.29.18
Pump is switched off and mains plug is removed from the
socket
Pump is clean and free of hazardous materials
Tubes removed from pump’s pneumatic inlet and outlet
Spare part/tool
Service Set (according to chapter 10)
Allen key 4 mm
Felt-tip pen
Stabilization diaphragm (if required)
Tab. 8
Always replace diaphragm and valve plates together to main-
tain the pump performance.
WARNING
Health hazard due to dangerous substances
in the pump!
Depending on the substance transferred, caustic
burns or poisoning are possible.
Wear protective clothing if necessary, e.g.
protective gloves.
Flush pump before replacing the diaphragm and
valve plates (see chapter 8.2.1).
Conditions
Spare parts/tools
Information on procedure