KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 6
PARAMETER DESCRIPTIONS
95
bPRM:19 – Float LC Set Gain
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘SET GAIN’ button on the Float Load Cell screen has been pressed.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Float Load Cell \ Row 2.
bPRM:20 – Spare
bPRM:21 – Reset to Factory Chain
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘RESET TO FACTORY DEFAULTS’ button in the Physical Limits screen has been
pressed.
KSS Workspace tree location (User Level = Basic): Knight WO# \ Hoist Configuration \ Physical Travel Limits
\ Row 3.
bPRM:22 – Set Overall Upper Travel Limit
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘SET TO CURRENT POSITION’ button in the Physical Limits screen has been pressed.
KSS Workspace tree location (User Level = Basic): Knight WO# \ Hoist Configuration \ Physical Travel Limits
\ Row 1.
bPRM:23 – Set Overall Lower Travel Limit
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘SET TO CURRENT POSITION’ button in the Physical Limits screen has been pressed.
KSS Workspace tree location (User Level = Basic): Knight WO# \ Hoist Configuration \ Physical Travel Limits
\ Row 2.
bPRM:24 – Reset Lift to Overall Limits
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘RESET TO PHYSICAL LIMITS’ button in the Lift Travel Limits screen has been pressed.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Lift Travel Limits \ Row 3.
bPRM:25 – Set Lift Upper Travel Limit
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘SET CURRENT POSITION’ button on the Lift Travel Limits screen has been pressed.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Lift Travel Limits \ Row 1.
bPRM:26 – Set Lift Lower Travel Limit
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘SET CURRENT POSITION’ button on the Lift Travel Limits screen has been pressed.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Lift Travel Limits \ Row 2.
bPRM:27 – Reset Float to Overall Limits
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘RESET TO PHYSICAL LIMITS’ button in the Float Travel Limits screen has been pressed.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Float Travel Limits \ Row 3.
bPRM:28 – Set Float Upper Travel Limit
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘SET CURRENT POSITION’ button on the Float Travel Limits screen has been pressed.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Float Travel Limits \ Row 1.
bPRM:29 – Set Float Lower Travel Limit
Variable Units: Boolean (0=Off, 1=On)
Description: The ‘SET CURRENT POSITION’ button on the Float Travel Limits screen has been pressed.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Float Travel Limits \ Row 2.
bPRM:30 – Spare