INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following product: 

OP9R 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this product is fitted) does not exceed the rating of 

the circuit cable, fuse, or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

Do not overload this accessory or subject it to conditions outside its rating 

 

This product is Class I and must be earthed 

 

This product is IP66 rated 

INSTALLATION 
Note:

 the unit should be fixed to a rigid flat surface as unevenness could cause damage to the product or affect 

operation 

 

Provide power to the required point of installation (refer to BS7671 for correct cabling methods) 

 

Remove the front assembly from the backbox and carefully lift off the gasket. Drill the required number 

of fixing holes in the backbox (see Fig. 1) 

 

Using the backbox as a template, mark the location for, and drill the fixing holes ensuring not to 

infringe with any gas/water pipes or electrical cables 

 

 

 

 

 

Fig. 1 

 

 

 

 

 
 

 

The backbox has drain hole drilling guides marked (see Fig. 2). Drilling a drain hole is advised if the 

unit is installed in a location subject to temperature fluctuations where a build-up of condensation may 

occur. It is not advised if the unit will be subject to high-pressure jets, as drilling a drain hole will reduce 

the IP rating. A 3-5mm hole should be drilled at the bottom back edge of the enclosure where marked. 

If wiring in conduit to the bottom entry, then the drain hole should be drilled at the lowest point of the 

conduit run not in the backbox 

 
 
 

INSTALLATION

Note: the unit should be fixed to a rigid flat surface as unevenness could cause damage to 
the product or affect operation
• Provide power to the required point of installation (refer to BS7671 for correct cabling 
   methods)
• Remove the front assembly from the backbox and carefully lift off the gasket. Drill the 
   required number of fixing holes in the backbox (see Fig. 1)
• Using the backbox as a template, mark the location for, and drill the fixing holes ensuring 
   not to infringe with any gas/water pipes or electrical cables

Fig. 1

Summary of Contents for OP9R

Page 1: ...INSTALLATION MAINTENANCE MANUAL OP9R...

Page 2: ...671 and current Building Regulations If in any doubt consult a qualified electrician Please isolate mains prior to installation or maintenance Check the total load on the circuit including when this p...

Page 3: ...1 Using the backbox as a template mark the location for and drill the fixing holes ensuring not to infringe with any gas water pipes or electrical cables INSTALLATION Note the unit should be fixed to...

Page 4: ...the backbox then wire as shown in Fig 3 ensuring that correct polarity is observed L Live brown E Earth green yellow N Neutral blue The backbox has drain hole drilling guides marked see Fig 2 Drilling...

Page 5: ...h conductors that are not insulated The earth terminal in the backbox is provided for convenience and does not need to be connected Check all electrical connections are secure with no loose strands of...

Page 6: ...ch on and check for correct operation For security and to prevent unwanted tampering with the product a lug feature with a 6mm hole is provided to accept a padlock or similar locking security device n...

Page 7: ...mote and take out the PCB Remove the old batteries and insert two new CR2016 batteries see Fig 4 Fig 4 WARNING To ensure continued safe and proper weatherproof operation the unit must not be left with...

Page 8: ...cessories reserve the right to alter product specification without prior notice GENERAL This product should be recycled in the correct manner when it reaches the end of its life Check local authoritie...

Page 9: ...15 863 RoHS 2021 341 ERP Safety Standards Full individual declarations and specific safety standards applicable to relevant product series can be found on our website www mlaccessories co uk We hereby...

Page 10: ...o 1095 The Ecodesign for Energy Related Products and Energy Information Lighting Products Regulations 2021 Included Legislation UK SI 2008 No 2852 UK REACH UK SI 2013 No 3113 WEEE Safety Standards Ful...

Page 11: ...Manufacturer ML Accessories Ltd Unit E Chiltern Park Boscombe Road Dunstable LU5 4LT www mlaccessories co uk EU Authorised Representative nnuks Holding GmbH Niederkasseler Lohweg 18 40547 D sseldorf G...

Reviews: