3
Knorr-Bremse Group
PD-203-360
Doc. No. Y250908 (EN - Rev. 001)
September 2016
The information contained herein is subject to alteration without notice and therefore may not be the latest release. Please check our website www.knorr-bremseCVS.com for the latest update or contact your local Knorr-Bremse representative.
The figurative mark “K” and the trademarks KNORR and KNORR-BREMSE are registered in the name of Knorr-Bremse AG. Additional terms and conditions apply; please refer to our website knorr-bremseCVS.com for full Disclaimer.
Note: If service work is carried out on a vehicle based on information provided herein, it is the responsibility of the workshop to ensure the vehicle is fully tested and in full
functional order before the vehicle is returned into service. Knorr-Bremse accepts no liability for problems caused as a result of appropriate tests not being carried out.
Copyright © Knorr-Bremse AG - all rights reserved, including industrial property rights applications. Knorr-Bremse AG retains any power of disposal, such as for copying and transferring.
Knorr-Bremse Systeme für Nutzfahrzeuge GmbH . Moosacher Straße 80 . 80809 Munich . Germany . Tel: +49 89 3547-0 . Fax: +49 89 3547-2767 . www.knorr-bremse.com . www.knorr-bremseCVS.com
KB4TA/KB4TA D System Components
C o m m e r c i a l V e h i c l e S y s t e m s
Park / Shunt Valve
Valve for trailers with air suspension
Features:
• Incorprates emergency brake function
• Priority to service braking system during charging
• Spring brakes held off during energy consumption test
• Spring brakes are fully applied when either the supply
line or reservoir pressure < 2.5 bar
• Charging Valve closing pressure 5.4 bar
Technical Data:
• Maximum operation pressure: . . . . . 10.0 bar
• Operating temperature range: . . . -40 °C to +80 °C
Valve for trailers with mechanical suspension
Features:
• Incorprates emergency brake function
• Priority to service braking system during charging
• Spring brakes held off during energy consumption test
• Spring brakes are fully applied when either the supply
line or reservoir pressure < 2.5 bar
Technical Data:
• Maximum operation pressure: . . . . . 10.0 bar
• Operating temperature range: . . . -40 °C to +80 °C
Y026787: 006: EN: Released: Fri Nov 11 11:18:50 CET 2016: