TEMON 4-C 

Doc. N°

 MO-0368-ING 

 

Microener. - Copyright 2010  

 

 

2.1 

Date 

01.12.2008

 

Rev. 

 

Pag. 

2

 

of 

14

 

 

 

 

1. Generality ______________________________________________________________________________________________________ 3

 

2. Introduction  ____________________________________________________________________________________________________ 3

 

3. Accessories and Options  _________________________________________________________________________________________ 3

 

4. Installation  _____________________________________________________________________________________________________ 3

 

5. Connection of the Thermometer Sensors ____________________________________________________________________________ 4

 

6. Output Relays ___________________________________________________________________________________________________ 4

 

7. Wiring Connection _______________________________________________________________________________________________ 5

 

8. Description Front Panel 

– Operators ________________________________________________________________________________ 6

 

9. Programming of the Device  _______________________________________________________________________________________ 7

 

9.1 - Selection of the HOLD function __________________________________________________________________________________ 7

 

9.2 - Selection of the number of active inputs ___________________________________________________________________________ 7

 

9.3 - Control ventilation ____________________________________________________________________________________________ 8

 

9.4 - Selection of the threshold of switch on and switch off ventilation ________________________________________________________ 8

 

9.5 - Selection threshold of disable ventilation  __________________________________________________________________________ 8

 

9.6 - Selection threshold of enable ventilation ___________________________________________________________________________ 8

 

9.7 - Selection of the alarm and tripped threshold ________________________________________________________________________ 9

 

9.8 - Selection of address network identification for the communication of the serial port (MODBUS-RTU protocol)  ____________________ 9

 

9.9 - Selection of baud rate _________________________________________________________________________________________ 9

 

9.10 - Selection data bit, parity and stop bit____________________________________________________________________________ 10

 

9.11 - Selection of the channel linked to the analogical output _____________________________________________________________ 10

 

9.12 - Configuration of output signal _________________________________________________________________________________ 10

 

9.13 - Configuration diagnostic probes  _______________________________________________________________________________ 11

 

9.14 - The exit of the programming phase _____________________________________________________________________________ 11

 

10. Modality Of Tripping And Restore  ________________________________________________________________________________ 12

 

10.1 - Alarm ____________________________________________________________________________________________________ 12

 

10.2 - Trip  _____________________________________________________________________________________________________ 12

 

10.3 - To silence alarm  ___________________________________________________________________________________________ 12

 

11. Diagnostic ____________________________________________________________________________________________________ 12

 

12. Visualization of the Maximum Measured Value of Temperature ________________________________________________________ 13

 

13. Visualization of the Channels With the Higher Temperature ___________________________________________________________ 13

 

14. Test of the Light Signalling ______________________________________________________________________________________ 13

 

15. Visualization of the Measured Temperature ________________________________________________________________________ 13

 

16. Exclusion of the Probe Inputs Not Used ___________________________________________________________________________ 13

 

17. Technical Features _____________________________________________________________________________________________ 14

 

18. Dimensions ___________________________________________________________________________________________________ 14

 

Summary of Contents for MICROENER TEMON 4-C

Page 1: ...TEMON 4 C Doc N MO 0368 ING Microener Copyright 2010 FW 2 1 Date 01 12 2008 Rev 0 TEMPERATURE MONITOR DEVICE TYPE TEMON 4 C OPERATION MANUAL...

Page 2: ...entification for the communication of the serial port MODBUS RTU protocol ____________________ 9 9 9 Selection of baud rate ____________________________________________________________________________...

Page 3: ...are available two levels of alarm alarm tripped that active the commutation of the relative output relay for signalling at distance or to disable the machine under control On front of the instrument...

Page 4: ...noises it s necessary to use the following indication for the wires of measure of the Pt100 to use probes with shielded wire connected at earth and wires twisted to separate the wires of the probes fr...

Page 5: ...TEMON 4 C Doc N MO 0368 ING Microener Copyright 2010 2 1 Date 01 12 2008 Rev 0 Pag 5 of 14 7 Wiring Connection...

Page 6: ...annels 5 LED FAULT of indication failure device or thermometric probes 6 LED HOLD of indication function of manual reset activated 7 LED FAN of indication activation output of ventilation 8 push butto...

Page 7: ...in the menu programming SET in this phase of programming the HOLD led switch on The Hold function allows to store the alarm condition that can be rearmed only manually with the RESET button when the...

Page 8: ...it s necessary to select the modality of functioning ventilation 9 5 Selection threshold of disable ventilation The FAN led on with fixed light indicates this phase of programming With and keys to se...

Page 9: ...ion of address network identification for the communication of the serial port MODBUS RTU protocol NOTE This set haven t mean for the models without the serial output RS485 option installed This phase...

Page 10: ...the highest temperature With and keys to select the set choice Confirm with ENTER 9 12 Configuration of output signal NOTE This set haven t mean for the models without the analogical output option in...

Page 11: ...n temperature FDC min 5 C max 30 C and after the time in which to do the control FDC min 10 max 90 period in seconds The key is used to increase the values while the key to decrease Confirm with ENTER...

Page 12: ...old value set the flashing optical signalling will be automatically deleted 11 Diagnostic The device is provided of the thermic probes diagnostic function The condition controlled on the measure input...

Page 13: ...inputs 1 and 2 On the right display on the front panel will appear the temperature of the measure channel hotter between the inputs 3 and 4 To come back in the standard modality of measure visualizat...

Page 14: ...m depth 120mm Enclosure thermoplastic self extinguishing as UL94 V0 working temperature 10 55 C humidity max 90 storing temperature 25 80 C standards electromagnetic compatibility CEI EN 50081 2 CEI E...

Reviews: