Measurement Operation
7
2. Place the housing front part with marking
towards the object being measured.
3. There will be three types of displays:
}
LCD displays different size of digits to
represent the strength of detected signal.
}
When the LCD displays OL, the buzzer beeps
and the red LED blinks.
Operation of Hold Mode
RANGE button
To avoid possibility of electric shock, do not
use Hold mode to determine if circuits are without
power. The Hold mode will not capture unstable or
noisy readings.
In order to avoid the hazard arising from
mistaken readings in insufficient lignt or poor vision,
please use display backlight function.
The Hold mode is applicable to all measurement
functions.
• Press HOLD to enter Hold mode; the Meter
beeps.
• Press HOLD again to exit Hold mode; the Meter
beeps.
• In Hold mode, is displayed.
• Press and hold HOLD/LIGHT for over 2 seconds
to turn the display backlight on.
• The display backlight will automatically off around
after 10 seconds.
To preserve battery life, the meter automatically turn
off if you do not turns the rotary switch or press any
button for around 15 minutes.
The meter can be activated by turning the rotary
switch or pressing any button.
To disable the sleep mode function, press BLUE
botton while turning on the meter.
• Maximum Voltage between any Terminals and
Grounding: Refer to the different ranges input
protection voltage.
• Fused Protection for μAmA Input Terminal:
1A H 240V ø6x25mm.
• Fused Protection for 10A Input Terminal:
10A H 240V ø6x25mm.
• Display
}
Maximum reading 4000 (frequency 9999),
analogue bar graph 41 segments
• Measurement Speed: Updates 2~3 times/second.
• Range: Auto or Manual
• Polarity Display: Auto
• Overload indication: Display OL
• Battery Deficiency: Display
• Press RANGE to enter the manual ranging mode;
the Meter beeps.
• Press RANGE to step through the ranges available
for the selected function; the Meter beeps.
• Press and hold RANGE for over 2 seconds to
return to autoranging; the Meter beeps.
MAX MIN button
• Press MAX MIN to start recording of maximum
and minimum values. Steps the display through
high (MAX) and low (MIN) readings. The Meter
enters manual ranging mode after pressing MAX
MIN button.
• Press and hold MAX MIN for over 2 seconds to
exit MAX MIN mode and return to the present
measurement range.
WARNING
WARNING
The Use of relative value mode
The REL mode applies to all measurement functions
except frequency/duty cycle measurement.
It subtracts a stored value from the present
measurement value and displays the result.
For instance, if the stored value is 20.0V and the
present measurement value is 22.0V, the reading
would be 2.0V. If a new measurement value is
equal to the stored value then display 0.0V.
To enter or exit REL mode:
• Press
REL
to enter REL mode, and the present
measurement range is locked and display “0” as
the stored value.
• Press
REL
again to reset the stored value
and exit REL mode.
The BLUE botton
It uses for selecting the required measurement func-
tion when there is more than one function at one
position of the rotary switch.
Turning on the Display backlight
Sleep mode
General Specifications
EF
• Temperature:
}
Operating: 0ºC to + 40ºC (32ºF to + 104ºF).
}
Storage: -10ºC to + 50ºC (14ºF to + 122ºF).
• Relative humidity:
}
75% @ 0ºC ~ 0ºC below
}
50% @ 30 - 40ºC.
• Battery type: One piece of 9V (NEDA 1604
or 6F22 or 006P).
• Under the influence of radiated radio-frequency
electromagnetic field phenomenon, the captioned
model have a measurement error, it will be back to
normal when the interference is removed.
• Dimensions (H x W x L): 180 x 87 x 47 mm.