background image

4

MOTOR CONTROL

On

Off

GROUNDING

1.  In the event of a malfunction or breakdown, grounding 

    provides a path of least resistance for the electric current,

    to reduce the risk of electric shock. This machine is

    equipped with an electrical cord that has equipment

    grounding conductor and a grounding plug. The plug must

    be plugged into a matching outlet that is properly installed

    and grounded in accordance with all local codes and

    ordinances.
2.  Do

 not modify the plug provided. If it will not fit the outlet,

    have the proper outlet installed by a qualified electrician.

3.  Improper connection of the equipment grounding conductor

    can result in the risk of electric shock. The conductor with 

    the green outer insulation (with or without a yellow stripe),

    is the equipment grounding conductor. If repair or

    replacement of the electrical cord is necessary, do not

    connect the equipment grounding conductor to a live

    terminal.
4.  Check

 with a qualified electrician or serviceman if the

    grounding instructions are not completely understood, or

    if there is doubt as to whether the machine in properly

    grounded.
5.  Using

 only three-wire extension cords that have

    three-prong grounding plugs and three pole receptacles

    that accept the tool’s plug.
6.  Repair or replace damaged or worn card immediately.
7.  This machine is intended for use on a circuit that has an

     outlet that looks like the one in illustration (A). The machine

    has a grounding plug that looks like the plug in illustration 

    (A). A temporary adapter, which looks like the adapter in

    illustration (B) and (C), may be used to connect the plug to

    a one pole receptacle, as shown in illustration (B), if a

    properly grounded outlet is not available. The temporary

    adaptor should only be used until a properly grounded

    outlet can be installed by qualified electrician. The three

    coloured rigid ear plug extending from the adapter, must be

    connected to a permanent ground such as a properly

    grounded outlet box.

Note: The type of electrical plug and receptacle differs from 

country to country
Caution:

 In Canada, only the grounding shown in figure (A) 

is acceptable. The extension cord should be a CSA certified 

S.J.T. type or something better.
Caution:

 In Australia, only the grounding shown in figure (D) 

is acceptable. The extension cord should be SSA certified.

Grounding pin

Cover of 

grounded 

outlet box

Adapter

Grounding 

terminal

Grounding pin

(A)

(B)

(C)

(D)

INLET AND OUTLET CONNECTOR

DIMENSIONS

Ø 5” Outlet

Ø 4” Inlet

Ø 4” Inlet

Summary of Contents for KN CP-2042B

Page 1: ...KN CP 2042B Dust collector 2 Colector de polvo H P...

Page 2: ...as described in this manual To avoid personal injury or damage to dust collection system use only recommended accessories Sparks inside the electrical parts can ignite flammable vapors or dust To avo...

Page 3: ...chment to do a job for which it was not designed 15 Maintain tools in top condition Keep tools sharp and clean for best and safest performance Follow instructions for lubricating and changing accessor...

Page 4: ...wire Power wire SWITCH WIRING DIAGRAM Toggle switch 1 On Off switch 1 Red Black Groundig Green R T 3 Black Groundig Green S T Red R MOTOR CONTROL The dust collector switch is located on the left side...

Page 5: ...extension cords that have three prong grounding plugs and three pole receptacles that accept the tool s plug 6 Repair or replace damaged or worn card immediately 7 This machine is intended for use on...

Page 6: ...he wrench Fig 1 2 Position the collector body and fan motor assembly into place Secure it to the base plate using the nuts and washers provided as shown in figure 2 Fig 2 3 Next mount the outlet I to...

Page 7: ...C 6 The upper bag support should be attached to the collector support as shown in figure 7 Fig 7 Fig 8 a m 7 Now attach one end the hose a to the collector body and the other end to the side hole of t...

Page 8: ...shutter can now be placed on the intake hole of the fan motor assembly as shown in figure 13 Fig 12 Fig 13 12 Install the inlet shutter to the collector fan motor assembly using a 3 16 pan flange hea...

Page 9: ...damaged 1 Incorrect power wiring 2 Overloaded 1 Motor is dirty 2 Motor is damaged 1 Inlet port blocked 2 Lower bag is full 3 Flexible hose is broken 4 Hose clamp is too loose 1 Casters are damaged 2...

Page 10: ...9 EXPLODED DIAGRAM OF DUST COLLECTOR PARTS...

Page 11: ...wrench 10 MM x 12 MM 1 33 Wrench hex 5 MM 1 Specification Q ty Part No D e s c r i p t i o n 1 Caster 4 2 Screw hex flange head 5 16 18UNC x 1 2 32 4 Base plate 1 5 Screw pan flange head 10 24 UNC x...

Page 12: ...e gas natural hidr geno o polvos explosivos como el polvo de carb n polvo de magnesio polvo de grano o p lvora No aspire nada que se est quemando o que est humeando como cigarros cerillos o ceniza cal...

Page 13: ...ue son muy peque as pueden causar riesgos de fuego o choques el ctricos Cuando use un cable de extensi n aseg rese que est en buen estado Vea Cables de extensi n en la secci n Operaci n para los calib...

Page 14: ...DE CABLEADO DEL INTERRUPTOR Interruptor de palanca 1 Interruptor de botones 1 Rojo Negro A tierra Verde R T 3 Negro A tierra Verde S T Rojo R CONTROL DEL MOTOR El interruptor del colector de polvo est...

Page 15: ...s instrucciones de aterrizaje no son comprendidas en su totalidad o si existe la duda en cuanto a que la m quina est debidamente aterrizada 5 S lo se permite usar extensiones el ctricas que cuenten co...

Page 16: ...Coloque en ensamblaje de cuerpo de colector y ventilador en su lugar Aseg relo a la base usando las tuercas y roldanas provistas como se muestra en la Fig 2 Fig 2 3 A continuaci n monte la junta I y...

Page 17: ...El soporte superior de bolsa se debe unir al soporte de colector como se muestra en la Fig 7 Fig 7 Fig 8 a m 7 Ahora una un extremo de la manguera a al cuerpo del colector y el otro extremo al orifici...

Page 18: ...ll 12 Instale el divisor de entrada en el ensamblaje de ventilador motor usando un tornillo 3 16 Apriete con un destornillador como se muestra en la Fig 13 1 Fig 13 1 13 El colector de polvo ahora est...

Page 19: ...1 Cableado incorrecto del motor 2 Sobrecargado 1 El motor est sucio 2 El motor est da ado 1 Puerto de entrada bloqueado 2 La bolsa inferior est llena 3 La manguera est rota 4 Abrazadera de manguera mu...

Page 20: ...19 DIAGRAMA DE PARTES DEL COLECTOR DE POLVO...

Page 21: ...12 MM 1 31 Cable de correinte 1 32 Llave espa ola 10 MM x 12 MM 1 33 Llave hexagonal 5 MM 1 Especificaci n Cant Part No D e s c r i p c i n 1 Rueda 4 2 Tornillo 5 16 18UNC x 1 2 32 4 Placa base 1 5 To...

Page 22: ...www knova com mx...

Reviews: