background image

KNOX VIDEO
RS8x8HB ROUTING SWITCHER

KNOX VIDEO

RS8x8HB ROUTING SWITCHER

Page 15

Page 16

In the non-verbose mode only the word DONE will be reported. In either mode,

an incorrect or meaningless command will cause the word ERROR to be reported.

Switches are ON when pushed to the right (as viewed from the back of the

panel).

4.5    DISABLING THE TIMED SEQUENCER

The Timed Sequencer can be activated accidently from the front panel

pushbuttons. To avoid this condition, disable the Timed Sequencer by putting
switch 4 in the ON position.

4.6    DISABLING BREAKAWAY AUDIO

To disable breakaway audio feature, turn switch 5 ON.

Summary of Contents for RS8x8HB

Page 1: ...stallation unauthorizedrepairormodification improper testing accidental or causes external to the product such as but not limited to excessive heat or humidity power failure or improper installation I...

Page 2: ...he equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between th...

Page 3: ...ctivates an automatic lamp test at powerup or when requested on the RS232 port Each time a routing command is received the current routing map can be reported on the RS232 port 1 3 DETAILSPECIFICATION...

Page 4: ...tor at the right rear as viewed from the back of the panel of the RS8x8HB and plug the power unit into a groundedAC power outlet of the voltage and frequency specified on the power unit There is no po...

Page 5: ...er up for switch configuration changes to take effect cycle the power input to the RS8x8HB In the verbose mode each time a routing command is sent the current routing map will be reported on the RS232...

Page 6: ...output and push the front panel button with that input number The row of LEDs will stop flashing and the lamp corresponding to the audio crosspoint will flash slowly while the LED corresponding to th...

Page 7: ...f commands to the routing switcher that will be held until the final command is received then all the commands are executed at the same time For all but the final command in the set use the form Exy E...

Page 8: ...the existing crosspoint pattern 3 5 ANSWERBACKMODES The user may choose between two modes of answerback verbose and non verbose Select the mode using position 3 of the programming switch located on t...

Page 9: ...1 ON OFF ON OFF SWITCH2 ON ON OFF OFF 4 4 SETTINGTHEANSWERBACKMODE The user may choose between two modes of answerback verbose and non verbose Select the mode using position 3 of the programming switc...

Page 10: ...ill cause the word ERROR to be reported Switches are ON when pushed to the right as viewed from the back of the panel 4 5 DISABLINGTHETIMEDSEQUENCER The Timed Sequencer can be activated accidently fro...

Reviews: